Functional imaging of murine hearts using accelerated self-gated UTE cine MRI
详细信息    查看全文
  • 作者:Abdallah G. Motaal (1) (2) (3)
    Nils Noorman (1) (2)
    Wolter L. de Graaf (1) (2)
    Verena Hoerr (4)
    Luc M. J. Florack (3)
    Klaas Nicolay (1) (2)
    Gustav J. Strijkers (1) (2) (5)

    1. Biomedical NMR
    ; Department of Biomedical Engineering ; Eindhoven University of Technology ; Eindhoven ; The Netherlands
    2. Center for Imaging Research and Education (CIRE)
    ; Eindhoven ; The Netherlands
    3. Department of Mathematics and Computer Science
    ; Eindhoven University of Technology ; Eindhoven ; The Netherlands
    4. Department of Clinical Radiology
    ; University Hospital of M眉nster ; M眉nster ; Germany
    5. Department of Biomedical Engineering and Physics
    ; Academic Medical Center ; Amsterdam ; The Netherlands
  • 关键词:Compressed sensing ; UTE ; Cardiac MRI ; Functional imaging
  • 刊名:The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging)
  • 出版年:2015
  • 出版时间:January 2015
  • 年:2015
  • 卷:31
  • 期:1
  • 页码:83-94
  • 全文大小:5,027 KB
  • 参考文献:1. McVeigh ER (1998) Regional myocardial function. Cardiol Clin 16:189鈥?06 CrossRef
    2. Watzinger N, Saeed M, Wendland MF, Akbari H, Lund G, Higgins CB (2001) Myocardial viability: magnetic resonance assessment of functional reserve and tissue characterization. J Cardiovasc Magn Reson 3:195鈥?08 CrossRef
    3. Kim RJ, Wu E, Rafael A, Chen E, Parker MA, Simonetti O, Klocke FJ, Bonow RO, Judd RM (2000) The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. N Engl J Med 343:1445鈥?453 CrossRef
    4. Geelen T, Paulis LEM, Coolen BF, Nicolay K, Strijkers GJ (2012) Contrast-enhanced MRI of murine myocardial infarction鈥攑art I. NMR Biomed 25:953鈥?68 CrossRef
    5. Kober F, Bernard M, Troalen T, Capron T (2012) Cardiovascular magnetic resonance of myocardial structure, function, and perfusion in mouse and rat models. Curr Cardiovasc Imag Rep 5:109鈥?15 CrossRef
    6. Shin T, Hu HH, Pohost GM, Nayak KS (2008) Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study. J Cardiovasc Magn Reson 10:57 CrossRef
    7. Peters DC, Korosec FR, Grist TM, Block WF, Holden JE, Vigen KK, Mistretta CA (2000) Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 43:91鈥?01 CrossRef
    8. Thedens D, Irarrazaval P, Sachs T, Meyer C, Nishimura D (1999) Fast magnetic resonance coronary angiography with a three-dimensional stack of spirals trajectory. Magn Reson Med 41:1170鈥?179 CrossRef
    9. Frahm J, Haase A, Matthaei D (1986)聽Rapid NMR imaging of dynamic processes using the FLASH technique. Magn Reson Med 3:321鈥?27
    10. Robson MD, Gatehouse PD, Bydder M, Bydder GM (2003) Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr 27:825鈥?46 CrossRef
    11. O鈥橞rien KR, Gabriel RS, Greiser A, Cowan BR, Young AA, Kerr AJ (2009) Aortic valve stenotic area calculation from phase contrast cardiovascular magnetic resonance: the importance of short echo time. J Cardiovasc Magn Reson 11:49鈥?0 CrossRef
    12. Hoerr V, Nagelmann N, Nauerth A, Kuhlmann M, Stypmann J, Faber C (2013) Assessment of functional cardiac parameters at high magnetic fields. J Cardiovasc Magn Reson 15:59 CrossRef
    13. Heijman E, Graaf WD, Niessen P, Nauerth A, Eys G, Graaf LD, Nicolay K, Strijkers GJ (2007) Comparison between prospective and retrospective triggering for mouse cardiac MRI. NMR Biomed 20:439鈥?47 CrossRef
    14. Nauerth A, Heijman E, Diekmann C (2006) Slice refocusing signal for retrospective reconstruction of CINE cardiac MR images. Proc Intl Soc Magn Reson Med 14, p 1648
    15. Coolen BF, Abdurrachim D, Motaal AG, Nicolay K, Prompers JJ, Strijkers GJ (2013)聽High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function. Magn Reson Med 69:648鈥?56
    16. Larson A, White R, Laub G, McVeigh E, Li D, Simonetti O (2004) Self-gated cardiac cine MRI. Magn Reson Med 51:93鈥?02 CrossRef
    17. Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182鈥?195 CrossRef
    18. Fessler JA, Sutton BP (2003)聽Nonuniform fast fourier transforms using min鈥搈ax interpolation. IEEE Trans Signal Process 51(2):560鈥?74
    19. Wech T, Lemke A, Medway D, Stork L-A, Lygate CA, Neubauer S, Kostler H, Schneider JE (2011) Accelerating cine-MR imaging in mouse hearts using compressed sensing. J Magn Reson Imag 34:1072鈥?079 CrossRef
    20. Otazo R, Kim D, Axel L, Sodickson DK (2010) Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI. Magn Reson Med 64:767鈥?76 CrossRef
    21. Gamper U, Boesiger P, Kozerke S (2008) Compressed sensing in dynamic MRI. Magn Reson Med 59:365鈥?73 CrossRef
    22. Buonincontri G, Methner C, Krieg T, Carpenter TA, Sawiak SJ (2014) Functional assessment of the mouse heart by MRI with a 1-min acquisition. NMR Biomed 27:733鈥?37 CrossRef
    23. Doneva M, Eggers H, Rahmer J, B枚rnert P, Mertins A (2008)聽Highly undersampled 3D golden ratio radial imaging with iterative reconstruction. Proceedings of the 16th annual meeting of ISMRM, Toronto, Canada, p 336
    24. Feng L, Grimm R, Block KT, Chandarana H, Kim S, Xu J, Axel L, Sodickson DK, Otazo R (2014)聽Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI. Magn Reson Med. doi:10.1002/mrm.24980
    25. Winkelmann S, Schaeffter T, Koehler T, Eggers H, Doessel O (2007) An optimal radial profile order based on the golden ratio for time-resolved MRI. IEEE Trans Med Img 26:68鈥?6 CrossRef
    26. Thompson RB, McVeigh ER (2004)聽Flow-gated phase-contrast MRI using radial acquisitions. Magn Reson Med 52:598鈥?04
    27. Bauer RW, Radtke I, Block KT, Larson MC, Kerl JM, Hammerstingl R, Graf TG, Vogl TJ, Zhang S (2013)聽True real-time cardiac MRI in free breathing without ECG synchronization using a novel sequence with radial k-space sampling and balanced SSFP contrast mode. Int J Cardiovasc Imag 29(5):1059鈥?067
    28. Hiba B, Richard N, Thibault H, Janier M (2007)聽Cardiac and respiratory self-gated cine MRI in the mouse: comparison between radial and rectilinear techniques at 7T. Magn Reson Med 58(4):745鈥?53
    29. Glover GH, Pauly JM (1992)聽Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 28:275鈥?89
    30. Bergin CJ, Glover GH, Pauly JM (1991) Lung parenchyma: magnetic susceptibility in MR imaging. Radiology 180:845鈥?48 CrossRef
    31. Du JA, Carlb M, Byddera M, Takahashib A, Chunga CB, Byddera GM (2010) Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone. J Magn Reson 207:304鈥?11 CrossRef
    32. Kr盲mer M, Herrmann K-H, Biermann J, Reichenbach JR (2014)聽Retrospective reconstruction of cardiac cine images from golden-ratio radial MRI using one-dimensional navigators. J Magn Reson Imag. doi:10.1002/jmri.24364
    33. Jung H, Park J, Yoo J, Ye JC (2010)聽Radial k-t FOCUSS for high-resolution cardiac cine MRI. Magn Reson Med 63:68鈥?8
    34. Bauer R, Radtke I, Uecker M, Zhang S, Block K, Graf T, Kerl J, Vogl T, Larson M True real-time cardiac MRI with radial K-space sampling in free breathing without ECG-synchronization鈥攊mproved image quality with iterative image reconstruction. Radiological Society of North America 2012 Scientific Assembly and Annual Meeting; 2012 Chicago, IL
    35. Seiberlich N, Lee G, Ehses P, Duerk JL, Gilkeson R, Griswold M (2011)聽Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA. Magn Reson Med 66:1682鈥?688
    36. Usman M, Atkinson D, Odille F, Kolbitsch C, Vaillant G, Schaeffter T, Batchelor P, Prieto C (2013) Motion corrected compressed sensing for free-breathing dynamic cardiac MRI. Magn Reson Med 70:504鈥?16 CrossRef
    37. Jong SD, Zwanenburg JJ, Visser F, Nagel RVD, Rijen HV, Vos MA, Bakker JM, Luijten PR (2011)Direct detection of myocardial fibrosis by MRI. J Mol Cell Cardiol 51(6):974鈥?79
    38. Nierop BV, Nelissen JL, Bax NA, Graaf L, Nicolay K, Strijkers GJ In vivo ultra short TE (UTE) MRI of mouse myocardial infarction. In: Proceedings of the 20th annual meeting of ISMRM, Melbourne, Australia, p 390
    39. Hiba B, Richard N, Janier M, Croisille P (2006)聽Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T. Magn Reson Med 55:506鈥?13
    40. Voiron J, Lamalle L (2006)聽Spiral MRI on rat brain and rat heart at 7 Tesla. In: Proceedings of the 14th annual meeting of ISMRM, Seattle, Washington, USA, p 3378
    41. O鈥橞rien KR,Myerson SG,Cowan BR, Young AA, Robson MD (2009)聽Phase contrast ultrashort TE: a more reliable technique for measurement of high-velocity turbulent stenotic jets. Magn Reson Med 62(3):626鈥?36
    42. Motaal AG, Coolen BF, Abdurrachim D, Castro RM, Prompers JJ, Florack LM, Nicolay K, Strijkers GJ (2012) Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction. NMR Biomed 26(4):451鈥?57 CrossRef
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Cardiology
  • 出版者:Springer Netherlands
  • ISSN:1573-0743
文摘

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700