Study on the Cracking Process of Cement-Based Materials by AC Impedance Method and Ultrasonic Method
详细信息    查看全文
  • 作者:Yue Li (1)
    Chun-e Sui (2) sce2008_tl@163.com
    Qing-jun Ding (3)
  • 关键词:Cement ; based materials – ; Bending process – ; AC impedance spectroscopy – ; Ultrasonic
  • 刊名:Journal of Nondestructive Evaluation
  • 出版年:2012
  • 出版时间:September 2012
  • 年:2012
  • 卷:31
  • 期:3
  • 页码:284-291
  • 全文大小:649.7 KB
  • 参考文献:1. Shi, M.: Impedance Spectroscopy of Concrete. China Railway Press (2003)
    2. McCarter, W.J., Gravin, S., Bouzid, N.: Impedance measurements on cement paste. J. Mater. Sci. Lett. 7, 1056–1057 (1988)
    3. Mccarter, W.J., Brousseau, R.: The AC response of hardened cement paste. Cem. Concr. Res. 20, 891–900 (1990)
    4. Brantervik, K., Niklasson, G.A.: Circuit models for cement based materials obtained from impedance spectroscopy. Cem. Concr. Res. 21, 496–508 (1991)
    5. Li, X., A, R., Yan, P.: Research on hydration degree of cement-FA complex binders. J. Build. Mater. 13, 584–588 (2010)
    6. Zhang, Y., Shi, M.: Study of the hydration process of cement-based materials by AC impedance technique. J. Build. Mater. 3, 109–112 (2000)
    7. Shi, M., Chen, Z.: Study of AC impedance on the pore structure of hardened cement paste. J. Build. Mater. 1, 30–35 (1998)
    8. Shi, H., Fang, Z.: Influence of FA on early hydration and pore structure of cement pastes. J. Chin. Ceram. Soc. 32, 95–98 (2004)
    9. Zhang, Z., Shi, M.: Study of cementitious activity of granulated blast furnace slag by AC impedance technique. J. Build. Mater. 8, 583–585 (2005)
    10. Zhang, Z., Shi, M.: Study of hydration mechanism of mineral admixture in concrete by AC impedance technique source. J. Build. Mater. 9, 366–369 (2006)
    11. Tian, M.: Study on electrical impedance of hardened cement paste with crack. Dissertation, Sichuan University, China (2006)
    12. Gu, P., Xu, Z., Xie, P., Beaudoin, J.J.: An AC impedance spectroscopy study of micro-cracking in cement-based composites during compressive loading. Cem. Concr. Res. 23, 675–682 (1993)
    13. Li, W.: Frequency-spectrum analysis of ultrasonic testing signal in concrete. Nondestructive Testing of Concrete Elements and Structures, 104–114 (1992)
    14. Bungey, H.: Ultrasonic testing to identify alkali-silica reaction in concrete. Br. J. Non-Destr. Test. 33, 227–231 (1991)
    15. Maslouhi, A.: Fatigue crack growth monitoring in aluminum using acoustic emission and acousto-ultrasonic methods (Special issue: Advanced Materials and Structures Response Prediction and Monitoring). Struct. Control Health Monit. 18, 790–806 (2011)
    16. Hatanaka, H., Kawano, Y., Ido, N., Hato, M., Tagami, M.: Ultrasonic testing with advanced signal processing for concrete structures. Nondestruct. Test. Eval. 20, 115–124 (2005)
    17. He, F., Wang, Z., Shi, L.: Ultrasonic testing technique for the inspection of defects in the corner of composites. J. Mater. Eng. 7, 80–84 (2011)
    18. Gu, P., Xu, Z., Xie, P., Beaudoin, J.J.: Application of AC impedance techniques in studies of porous cementitious material. I. Influence of solid phase and pore solution on high frequency resistance. Cem. Concr. Res. 23, 531–534 (1993)
    19. Prassianakis, I.N.: Ultrasonic testing of non-metallic materials: concrete and marble. Theor. Appl. Fract. Mech. 42, 191–198 (2004)
  • 作者单位:1. The Key Lab of Urban Security & Disaster Engineering, Beijing University of Technology, Beijing, 100124 China2. The Key Lab of Coast Civil Structure Safety School of Civil Engineering, Tianjin University, Tianjin, 300072 China3. School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070 China
  • ISSN:1573-4862
文摘
By using AC impedance spectroscopy (ACIS), this paper studied the changes of electrochemical parameters of cement paste mixed with fly ash (FA), ground blast furnace slag (GBFS) and silica fume (SF) during the process of bending. The results showed that: the AC impedance parameter R s decreased with the increase of stress imposed on the specimens. Under the same condition of W/B and stress, for R s there were group D with SF > group C with GBFS > group A of cement paste > group B with FA, which indicated that the porosity or cracks within the samples were group B > A > C > D, and with the increase of stress, the change rate of R s of group D, C and A was less than group B. At the same time, ultrasonic method was used to test the changes of sonic time and first wave amplitude during the bending process, and the results are agree with the changes of ACIS parameters.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700