Label-free detection of biotin using nanoporous TiO2/DNA thin-film coated wavelength interrogated surface plasmon resonance sensors
详细信息    查看全文
  • 作者:Qiushun Li (1)
    Hao He (2)
    Junnan Wang (3)
    Hui Zheng (1)
    Jianguo Shi (1)
    Mingyu Li (4)
    Wenfei Dong (2)
    Zhimei Qi (5)
  • 关键词:Nanoporous film ; Sensing sensitivity ; Biotin ; Wavelength interrogated surface plasmon resonance
  • 刊名:Chemical Research in Chinese Universities
  • 出版年:2014
  • 出版时间:February 2014
  • 年:2014
  • 卷:30
  • 期:1
  • 页码:157-162
  • 全文大小:782 KB
  • 作者单位:Qiushun Li (1)
    Hao He (2)
    Junnan Wang (3)
    Hui Zheng (1)
    Jianguo Shi (1)
    Mingyu Li (4)
    Wenfei Dong (2)
    Zhimei Qi (5)

    1. Key Laboratory of Biosensor of Shandong Province, Biology Institute of Shandong Academy of Sciences, Jinan, 250014, P. R. China
    2. Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China
    3. The Second Hospital of Jilin University, Changchun, 130041, P. R. China
    4. State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou, 310027, P. R. China
    5. State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, 100190, P. R. China
  • ISSN:2210-3171
文摘
The sensing sensitivity of the wavelength interrogated surface plasmon resonance(WISPR) biosensor could be improved by self-assembly of nanoporous thin-film of TiO2 nanoparticles/DNA(TiO2/DNA) n (n is the number of bilayer) on wavelength interrogated surface plasmon resonance(WISPR) chips. The growth behavior and surface structure of the nanoporous thin-film were investigated by UV-Vis spectroscopy and scanning electron microscopy, respectively. The home-made WISPR sensor with Krestchmann configuration consisted of a tungsten-halogen lamp as a photon source and a CCD camera as the detector. After the deposition of (DNA/TiO2) n thin film on WISPR chips, the resonance peak of the reflection spectra appeared in air. With the increases of n, the resonance wavelength gradually red shifted, which is consistent with the simulated results. After the optimization of the porous film, the WISPR biosensor was utilized to detect low-molecular-weight analytes, such as biotin. The result demonstrates that the sensitivity of [poly(styrene sulfonate)/polyally lamine hydrochlorides]5(PSS/PAH)5 could be 4 times higher than that of polyelectrolyte multilayer modified WISPR sensor.