Monitoring of pulsed proton beams using free-air ionization chambers with petal shape electrodes
详细信息    查看全文
  • 作者:D. A. Zhidkov (1)
    V. I. Kostyuchenko (1)
    M. F. Lomanov (1)
    O. B. Ryazantsev (1)
    V. S. Khoroshkov (1)

    1. Alikhanov Institute for Theoretical and Experimental Physics
    ; National Research Centre Kurchatov Institute ; ul. Bol鈥檚haya Cheremushkinskaya 25 ; Moscow ; 117218 ; Russia
  • 刊名:Instruments and Experimental Techniques
  • 出版年:2015
  • 出版时间:January 2015
  • 年:2015
  • 卷:58
  • 期:1
  • 页码:146-152
  • 全文大小:567 KB
  • 参考文献:1. Khoroshkov, V.S., / Vvedenie v tekhniku protonnoi luchevoi terapii (Introduction into Proton Therapy Technique), Moscow: Uchebn.-Nauchn. Tsentr Dovuz. Obraz., 2001.
    2. Klenov, G.I. and Khoroshkov, V.S., / Med. Fiz., 2005, no. 3, p. 16.
    3. Klenov, G.I. and Khoroshkov, V.S., / Med. Fiz., 2005, no. 4, p. 9.
    4. Khoroshkov, V.S., / Phys. At. Nucl., 2006, vol. 69, no. 10, p. 1724. CrossRef
    5. Chu, W.T., Ludewigt, G.A., and Renner, T.R., / Rev. Sci. Instrum., 1993, vol. 64, p. 2055. CrossRef
    6. Poppea, B., Blechschmidt, A., and Djouguela, A., / Med. Phys., 2006, vol. 33, no. 4, p. 1005. CrossRef
    7. Nishio, T., Kataoka, S., Tachibana, M., Matsumura, K., Uzawa, N., Saito, H., Sasano, T., Yamaguchi, M., and Ogino, T., / Phys. Med. Biol., 2006, vol. 51, p. 1249. CrossRef
    8. Press, W.H., Teukolsky, S.A., Vetterling, W.T., and Flannery, B.P., / Numerical Recipes in Fortran, Cambridge: Cambridge University, 1992, 2nd ed.
  • 刊物类别:Physics and Astronomy
  • 刊物主题:Physics
    Measurement Science and Instrumentation
    Electronic and Computer Engineering
    Physical Chemistry
    Russian Library of Science
  • 出版者:MAIK Nauka/Interperiodica distributed exclusively by Springer Science+Business Media LLC.
  • ISSN:1608-3180
文摘
It has been theoretically and experimentally shown that, using stepwise rotation of a multielectrode free-air ionization chamber to measure the parameters of a pulsed proton beam, it is possible to substantially increase the accuracy in determining both the centroid position of the beam cross section, as well as the transverse distribution of the dose produced by the beam. The linear operation modes of the chambers are identified and the system characteristics are investigated. The inaccuracy in determining the centroid position of the beam cross section is