XRD, micro-XANES, EMPA, and SIMS investigation on
详细信息   full">在线全文   full.pdf">PDF全文下载
摘要

Selected phlogopite flakes from Mt. Vulture in southern Italy were studied using a combination of single-crystal techniques: electron microprobe analysis (EMPA), secondary ion mass spectrometry (SIMS), single-crystal X-ray diffraction (SCXRD), and micro-X-ray absorption near-edge spectroscopy (XANES). The latter technique was employed to analyze the structure of the Fe-K absorption edge over the region from 7080–8100 eV and to determine Fe3+/∑Fe at a micrometer scale, albeit with large error bars due to known effects of orientation on pre-edge energy.

The annite component, Fe/(Mg+Fe), of the samples studied ranged from 0.16 to 0.31, the Ti content from 0.11 to 0.27 atoms per formula unit (apfu) and the Ba content from 0.03 to 0.09 apfu. SIMS analysis showed H2O (wt%) = 1.81–3.30, F (wt%) = 0.44–1.29, and Li2O (wt%) = 0.001–0.027. The intra single-crystal chemical variability for major/minor elements (Mg, Fe, Al, Ba, Ti, and K) was found particularly significant for samples VUT191_11 and PG5_1, less significant for the other samples of the set. SIMS data relative to crystals VUT187_24, VUT191_10, VUT191_11, and VUT187_28 showed a noteworthy variation in the concentrations of some light elements (H, Li, and F) with coefficient of variation CV (as 1σ%) up to ~18% for H2O.

The analyzed micas belong to the 1M polytype. Structure refinements using anisotropic displacement parameters were performed in space group C2/m and converged at 3.08 ≤ R ≤ 3.63, 3.32 ≤ Rw ≤ 3.98%. Micro-XANES results yielded Fe3+/∑Fe from 51–93%. Previous Mössbauer data from powdered samples suggested Fe3+/∑Fe values ranging from 49–87%. However, the Fe3+ content determined by both techniques is sometimes remarkably different, in part because of the large errors (±10–15%) presently associated with the micro-XANES technique and in part because the Fe3+ content of a single crystal may significantly depart from the average value obtained from routine Mössbauer analysis.

The combination of EMPA, SIMS, and micro-XANES resulted in the characterization of the samples at a comparable spatial scale. By means of in-situ data and the results of crystallographic investigations, the occurrence of different relative amounts of M3+-oxy [VIM2+ + (OH)VIM3+ + O2− + ½H2↑], Ti-oxy substitutions [VIM2+ + 2(OH)VITi4+ + 2O2− + H2↑], and Ti-vacancy (□) substitution (2VIM2+VITi4+ + VI□) was ascertained for the studied samples.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700