Compressive strength of circular concrete filled steel tube columns
详细信息查看全文 | 推荐本文 |
摘要
An experimental study was undertaken to investigate the behaviour of 24 concrete-filled steel tube (CFST) columns, loaded concentrically in compression to failure. Variables in the tests include the length, diameter, strength of the steel tubes and the strength of the concrete. The large slenderness ratio caused all composite columns in Series 1 to fail by overall flexural buckling. Although overall flexural buckling was also experienced in the composite columns of Series 2 tests, the stockier columns failed by crushing of the concrete and yielding of the steel tube. A comparison of the experimental results with the loads predicted by the South African code (SANS 10162-1) and Eurocode 4 (EC4) shows that the codes are conservative by 8.4%and 13.6%, respectively, for Series 1 tests, and 10.5 and 20.2%, respectively, for Series 2 tests. A plot of the compressive load versus the vertical deflection shows the composite columns to be fairly ductile.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700