One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: Serum metal ion levels and clinical outcomes
详细信息查看全文 | 推荐本文 |
摘要
| Figures/TablesFigures/Tables | ReferencesReferences

Summary

Introduction

The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with large-diameter implants are causing concern. To determine whether these events are related to the geometry and metal composition of the prosthesis components, we conducted a prospective study of clinical outcomes and serum chromium and cobalt levels 1 year after implantation of three different acetabular cups.

Hypothesis

Serum levels of metal ions are comparable with different types of large-diameter metal-on-metal total hip prostheses.

Patients and methods

We compared 24 Durom鈩?cups (D), 23 M2a Magnum鈩?cups (M2a), and 20 Conserve Total鈩?(C) cups regarding serum chromium and cobalt levels, Postel-Merle d鈥橝ubign茅 (PMA) scores and Oxford Hip Scores (OHS), as well as radiographic cup orientation and position at 1-year follow-up. Mean age was 66 years (45-85 years), mean body mass index was 28 Kg/m2 (18-45), patients were almost equally divided between males and females, and the reason for hip replacement was primary hip osteoarthritis in 65 patients and avascular necrosis in two. Metal ions were assayed in serum from blood drawn through non-metallic catheters, using mass spectrometry.

Results

Dislocation occurred in two patients (one D and one M2a) and revision to change the bearing couple was required in two patients in the D group. Serum cobalt levels in the C group were significantly higher (P = 0. 0003) than in the two other groups (7.5 渭g/L versus 2. 7 渭g/L with D and 2. 2 渭g/L with M2a). Clinical outcomes were better in the M2a group (PMA, 17.7 [16-18]; and OHS, 15.2 [12-30]; P < 0.05). The PMA score and OHS were 17.5 (16-18) and 18.2 (12-42), respectively, with D; and 16.75 (10-18) and 22. 2 (12-42), respectively, with C cups. When all three cup models were pooled, serum ion levels were higher in patients with pain than without pain (chromium, 7.1 渭g/L versus 2.1 渭g/L [P = 0.002], and cobalt, 8 渭g/L versus 2.6 渭g/L [P = 0.0004]).

Discussion

Serum chrome and cobalt levels increased after metal-on-metal total hip replacement, and the increase was greater with large-diameter implants than previously reported with 28-mm implants. Persistent pain was significantly associated with higher metal ion levels, with a probable cobalt cut-off of about 8 渭g/L. Differences in modular head-neck concepts may explain the observed variations.

Level of evidence

III, prospective comparative study.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700