Seven-month-old female Sprague-Dawley rats were used. Fourteen rats had ovariectomy, and nine rats had sham surgery. Magnetic resonance imaging (MRI) of sagittal midsection of lumbar spine was performed with a 1.5-T magnet. Dynamic MRI was performed after a bolus injection of Gd-DOTA (0.3 mmol/kg) through tail vein. Eight hundred images were acquired at 0.6 s per acquisition. Regions of interests were drawn over three discs per rat. Maximum enhancement (Emax) and enhancement slope (Eslope) were evaluated. MRI was carried out at baseline and 8 weeks postsurgery.
All disc enhancements demonstrated an initial fast wash-in phase followed by a second slower wash-in phase. For initial wash-in phase, E1max and E1slope of all rats remained unchanged at the two time points. For second wash-in phase, E2max and E2slope of control rats remained unchanged, while with ovariectomized rats, E2max showed reduction at 8 weeks (4.5%卤5.6%) compared to baseline (10.3%卤6.3%, P=.037), and E2slope was lower at 8 weeks (0.015卤0.017) than the baseline (0.029卤0.022), although it was not statistically significant (P=.101).
Ovariectomy induced detectable decrease in second wash-in phase of contrast agent into lumbar disc.