From March 2006 through March 2011, 86 patients with chronic heart failure underwent implantation of a HeartMate II (Thoratec Corp, Pleasanton, CA) LVAD. Clinical records of these patients were reviewed to identify patients who underwent NCS while on LVAD support, with a focus on peri-operative death, bleeding, thrombosis, and device malfunction, as well as management of pre-operative anti-coagulation.
While on CF-LVAD support, 20 patients underwent 25 NCSs, comprising 13 major and 12 minor procedures. Operations were performed electively in 22 and as emergencies in 3. No peri-operative deaths, thromboembolic complications, or device malfunctions occurred. The incidence of bleeding requiring transfusion of packed red blood cells was 36.0%, including 25%of patients undergoing minor NCSs and 46.2%undergoing major NCSs (p = 0.004). All bleeding complications occurred in patients on both warfarin and aspirin pre-operatively. The only significant differences between patients who did and did not require transfusion were pre-operative warfarin use and significantly higher pre-operative international normalized ratio in the transfused group (1.9 卤 0.4 vs 1.4 卤 0.3; p = 0.008).
Non-cardiac operations can be performed safely in patients with CF-LVADs. It may possible to reduce peri-operative bleeding by lowering pre-operative anti-coagulation goals, especially before major surgery. However, additional analysis is required to determine if this can be performed safely.