In order to compute the distance between the transducers (speakers) and object to be localized (microphone), time-of-arrival measurements of acoustic signals consisting of Binary Phase Shift Keying modulated Gold sequences are performed. This DS-CDMA scheme assures accurate distance measurements and provides immunity to noise and interference.
Two methods have been proposed for location estimation. The first method takes the average of four location estimates obtained by trilateration technique. In the second method, only a single robust position estimate is obtained using three distances while the least reliable fourth distance measurement is not taken into account.
The system始s performance is evaluated at positions from two height levels using system parameters determined by preliminary experiments. The precision distributions in the work area and the precision versus accuracy plots depict the system performance. The proposed system provides location estimates of better than 2 cm accuracy with 99%precision.