A novel technique for gaining IV access in a mouse model is presented. Using a cut-down approach, the facial vein is identified through an incision from anterior to the external auditory meatus to posterior to the lateral ispilateral canthus. A small gage needle (30 gauge) may be inserted to inject medications. A high success rate (93%) as determined by direct visualization is achieved. The technique would prove especially useful for animals slated for kinematic testing as the incision does not interfere with the animal's ventral surface.