Comparison of pseudophakic dysphotopsia with Akreos Adapt and SN60-AT intraocular lenses
详细信息查看全文 | 推荐本文 |
摘要

Purpose

To determine the relative incidence of unwanted light images with the AcrySof SN60-AT intraocular lens (IOL) (Alcon) and the Akreos Adapt (Bausch & Lomb) IOL.

Setting

The Eye Clinic, Sir Charles Gairdner Hospital, Nedlands, Australia.

Methods

In a prospective randomized study of 61 patients who had cataract surgery, the relative incidence of unwanted light images with 2 biconvex acrylic double square-edged IOLs, the SN60-AT and Akreos Adapt, was compared. Patients were followed at 1 week and for a minimum of 6 weeks. At both follow-ups, patients were asked to rate their experience of dysphotopic phenomenon according to a set of questionnaire criteria. The Mann-Whitney test was used to analyze the ordinal data.

Results

All 61 patients were interviewed at both stages of follow-up. The mean follow-up was 8 weeks ± 2 (SD). At 1 week, there was significantly more dysphotopsia (positive and negative) with the SN60-AT IOL (37.5%) than with the Akreos Adapt IOL (24.1%) (P = .042). Significantly more patients with the SN60-AT IOL reported negative dysphotopsia at 1 week only. At 8 weeks, the incidence of positive and negative dysphotopsia declined to 31.3%and 20.7%in the SN60-AT group and Akreos Adapt group, respectively, and there was no longer a statistically significant difference between the 2 groups.

Conclusions

More patients with the SN60-AT IOL than with the Akreos Adapt IOL reported dysphotopsia. One week postoperatively, the difference was significant. The difference was primarily a result of the higher incidence of negative dysphotopsia with the SN60-AT IOL. At 8 weeks, the incidence of all types of light phenomena was significantly lower in both groups.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700