Experimental study on smoke movement leading to glass damages in double-skinned façade
详细信息查看全文 | 推荐本文 |
摘要
Fire hazard of the new architectural feature – double-skinned façade was examined experimentally. Full-scale burning tests on part of the design feature were carried out in a facility developed in a remote area in Northeast China. A total of eight tests were performed to demonstrate how the depth of cavity of a double-skinned façade affects the smoke movement. Surface temperature and heat flux received on the test panels are presented. Cracking patterns found on the glass panels are also observed. The measured results would give the possible smoke movement pattern inside the air cavity.

By examining the results for cavity depth of 0.5, 1.0 and 1.5 m, it is found that a deeper cavity might give better safety under the scenario studied. The outer glass panel would be broken rapidly for the cavity of 0.5 m deep. Double-skinned façade with a cavity of 1.0 m deep appeared to be very risky as glass panels above broke most among the different cavity depths. The inner glass panel might be broken before the outer panel. This would give an undesirable outcome.

Other separation distances of the two skins should be further examined to give optimum design of cavity depth. Other factors affecting flame and smoke movement should be further investigated.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700