In order to prevent the containment and other safety relevant components from incurring serious damage caused by a detonation of the hydrogen/air-mixture generated during a severe accident in light water reactors (LWR) passive autocatalytic recombiners (PAR) are used for hydrogen removal in an increasing number of European plants. These devices make use of the fact that hydrogen and oxygen react exothermally on catalytic surfaces generating steam and heat.