Change of the ambient particle size distribution in East Germany between 1993 and 1999
详细信息查看全文 | 推荐本文 |
摘要
Size distribution of particle number concentrations in the geometric equivalent diameter range 0.01–2.5μm were determined in three communities, Zerbst, Bitterfeld and Hettstedt of the state of Sachsen-Anhalt in Eastern Germany, in the first half of 1993 and 1999. A Mobile Aerosol Spectrometer (MAS) consisting of a differential mobility particle spectrometer (DMPS) and a laser aerosol spectrometer (LAS-X) were used for size-selective particle number concentration measurements from which mass concentrations were derived based on an apparent mean density of the ambient aerosol of the closely situated city of Erfurt.