Analysis of laboratory sample rejections in the pre-analytical stage at an oncology center
详细信息查看全文 | 推荐本文 |
摘要
<h4 class="h4">Backgroundh4>Effective patient management depends on the accuracy of laboratory results. Sample collection errors constitute an important reason for repeat collections. This study was conducted at the laboratory diagnostic services of a tertiary care oncology center with a hematopoietic stem cell transplant unit to determine the common causes of sample rejections and see the effects of corrective action.<h4 class="h4">Methodsh4>

A retrospective, intervention and prospective analysis of the samples rejected from the total samples received in our laboratories, during a nine month period from January to September 2011 was undertaken. Causes of sample rejections were determined and intervention in the form of training relevant staff was instituted.<h4 class="h4">Resultsh4>

Out of 32,548 samples received during Jan-Sep 2011, 177 samples (0.54%) were rejected. The most common reasons for rejection in hematology and biochemistry areas were clotted blood specimen (51.2%), improperly labeled specimen containers (14.46%) and hemolyzed blood samples (11.45%). For microbiology these included labeling errors, collection of specimen in wrong containers and specimen collection date and time not being entered, unacceptable specimen source and delayed transit time (18.2%each).<h4 class="h4">Conclusionsh4>

Directed interventions may help reduce the incidence of sample rejections.