Durability of peel bond of resilient denture liners to acrylic denture base resin
详细信息查看全文 | 推荐本文 |
摘要

Purpose

The purpose of this study was to determine the durability of the peel bond of commercial resilient denture liners to a denture base resin using a thermal cycling test.

Methods

Eight commercial resilient denture liners (five silicone and three acrylic) were used in the study. The samples were exposed to thermal cycles between 5 掳C and 55 掳C for 1 min for 0, 1,250, 2,500, 5,000 and 10,000 cycles. The test samples were placed under tension until failure in a materials testing machine using a crosshead speed of 20 mm/min. The modes of debonding were characterized as tear, peel or snap. Statistical analysis was performed using one-way and two-way analysis of variance and Student-Newman-Keuls multiple comparison tests ( = .05).

Results

A significant difference was found between different resilient denture liners for peel bond strength at 0 cycles. No extreme influence on the peel bond strength was observed under any of the thermal cycles. The snap mode of debonding was observed in most samples of all materials for all cycles.

Conclusion

All resilient denture liners tested had a sufficiently strong bond to the denture base resin. Within the limitations of this study, the results show that all of the materials were acceptable for clinical use, having met the accepted adequate bond strength for resilient denture liners of 0.45 MPa.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700