A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung
详细信息查看全文 | 推荐本文 |
摘要
Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning.

Methods and Materials: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose–function histogram (DFH). The plans were compared using DFHs and F20/F30 values (Fx is the functional lung receiving dose above x Gy).

Results: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F20 and F30 values were reduced for all patients by an average of 13.6%± 5.2%and 10.5%± 5.8%, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose “give-take” between SPECT regions during redistribution.

Conclusions: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700