Distal biceps tendon rupture: An in vitro study
详细信息查看全文 | 推荐本文 |
摘要

Background

Options for repair of distal biceps tendon ruptures are well-described. However, scant data exist in the literature regarding failure strength of the native tendon. We hypothesize that a) the distal biceps tendon failure strength is sensitive to loading angle, and b) the failure strength is greater than what has been previously reported in the literature.

Methods

15 radii were potted in a simulated supine position, and the native tendon was pulled from the tuberosity at angles of 90, 60, and 30掳 of flexion (5 per group) relative to the long axis of the radius. The failure load and stiffness were recorded and compared.

Findings

The native tendon's mean failure load tended to increase as flexion angle decreased. Due to the large variability in strength, mean failure loads of the 90掳 (mean 358 (SE 117 N)), 60掳 (mean 617 (SE 141 N)), and 30掳 (mean 762 (SE 130 N)) groups were not statistically different from each other (P = 0.12). The mean stiffness results for each group (mean 501 (SE 176 N/mm), mean 763 (SE 226 N/mm), and mean 756 N (SE 179 N/mm), respectively) were not significantly different from each other (P > 0.6).

Interpretation

The load to failure of the distal biceps tendon may be higher than what has previously been reported, and may be dependent on the elbow flexion angle. Though this difference may be attributed to the difference in methodology it should be taken into account during consideration of repair and rehabilitation.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700