A model for quantitative changes in the magnetic resonance parameters of muscle in children after therapeutic irradiation
详细信息查看全文 | 推荐本文 |
摘要
>Purpose/Objective

This study aimed to develop objective models of radiation effects on musculature in children with soft tissue sarcoma using treatment dosimetry and clinical and quantitative magnetic resonance imaging (MRI) parameters that may be used to guide treatment planning or predict side effects.

Methods

In the initial 13 patients undergoing external beam radiation therapy (RT) on a Phase II study of conformal or intensity-modulated RT for the treatment of soft tissue sarcoma approved by an Institutional Review Board, we evaluated quantitative MRI changes in the musculature to assess radiation-related treatment effects. Patients with soft tissue sarcoma, including Ewing's sarcoma, had quantitative T<sub>1sub>, T<sub>2sub> and dynamic enhanced MRI (DEMRI) performed before, during (Week 4) and after RT (Week 12). Regions of interest were selected in consistent locations within and outside the high-dose regions (on ipsilateral and contralateral sides when available). Mean RT dose, T<sub>1sub>, T<sub>2sub> and DEMRI parameters were calculated and modeled using a mixed random coefficient dose model.

Results

The mean doses to the high- and low-dose regions were 56.4 Gy (41.8–75.3 Gy) and 13.0 Gy (0.1–37.5 Gy), respectively. Compared with tissues distant from the tumor bed, maximal enhancement was significantly increased in tissues adjacent to the tumor/tumor bed prior to RT (60.6 vs. 44.2, P=.045) and remained elevated after 12 weeks. T<sub>1sub> was significantly elevated in tissues adjacent to the tumor bed prior to RT (942.4 vs. 759.0, P=.0078). The slope of longitudinal change in T<sub>1sub> was greater for tissues that received low-dose irradiation than those that received high-dose irradiation (P=.0488). The effect of dose on the slope of T<sub>2sub> was different (P=.0333) when younger and older patients are compared.

Conclusions

Acute affects of irradiation in muscle are quantifiable via MRI. These models provide evidence that quantifiable MRI parameters may be correlated with patient parameters of radiation dose and clinical factors including patient age. Long-term follow-up will be required to determine if acute changes correlate with clinically significant late effects.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700