Full Utilization of Silt Density Index (SDI) Measurements for Seawater Pre-Treatment
详细信息    查看全文 | 下载全文 | 推荐本文 |
  • 作者:Chun-Hai WeiStephanie LaborieRoger BEN AimGary Amy
  • 会议时间:2012-06-26
  • 关键词:Fouling potential ; Organic colloids ; SDI ; Seawater ; Standard blocking
  • 作者单位:Chun-Hai Wei(Desalination and Reuse Center, King Abdullah University of Science and Technology, Saudi Arabia Laboratoire d'Ingenierie des Systemes Biologiques et des Precedes, Departement Genie des Procedes et Environnement, Institut National des Sciences Appliquees de Toulouse, France)Stephanie Laborie(Laboratoire d'Ingenierie des Systemes Biologiques etdes Precedes, Departement Genie des Procedes et Environnement, Institut National des Sciences Appliquees de Toulouse, France)Roger BEN Aim(Laboratoire d'Ingenierie des Systemes Biologiques et des Precedes, Departement Genie des Procedes et Environnement, Institut National des Sciences Appliquees de Toulouse, France Institute for Filtration and Separation Techniques (IFTS), France)Gary Amy(Institute for Filtration and Separation Techniques (IFTS), France)
  • 母体文献:2012青岛国际脱盐大会论文集
  • 会议名称:2012青岛国际脱盐大会
  • 会议地点:青岛
  • 主办单位:中国金属学会
  • 语种:chi
  • 分类号:S75;O4
摘要
In order to clarify the fouling mechanism during silt density index (SDI) measurements of seawater in the seawater reverse osmosis (SWRO) desalination process, 11 runs were conducted under constant-pressure (207 kPa) dead-end filtration mode according to the standard protocol for SDI measurement, in which two kinds of 0.45 |im membranes of different material and seawater samples from the Mediterranean including raw seawater and seawater pre-treated by coagulation followed by sand filtration (CSF) and coagulation followed by microfiltration (CMF) technologies were tested. Fouling mechanisms based on the constant-pressure filtration equation were fully analyzed. For all runs, only t/(V/A) ~ t showed very good linearity (correlation coefficient R2>0.99) since the first moment of the filtration, indicating that standard blocking rather than cake filtration was the dominant fouling mechanism during the entire filtration process. The very low concentration of suspended solids rejected by MF of 0.45 urn in seawater was the main reason why a cake layer was not formed. High turbidity removal during filtration indicated that organic colloids retained on and/or adsorbed in membrane pores governed the filtration process (i.e., standard blocking) due to the important contribution of organic substances to seawater turbidity in this study. Therefore the standard blocking coefficient ks, i.e., the slope of t/(V/A) ~ t, could be used as a good fouling index for seawater because it showed good linearity with feed seawater turbidity. The correlation of SDI with ks and feed seawater quality indicated that SDI could be reliably used for seawater with low fouling potential (SDI15min<5) like pre-treated seawater in this study. From both ks and SDI, the order of fouling potential was raw seawater > seawater pre-treated by CSF > seawater pre-treated by CMF, indicating the better performance of CMF than CSF.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700