摘要
通过详细剖析国内某大型水电站厂房内及廊道吊物孔的安全现状和存在的安全隐患,并结合实际情况,给出合理改造的意见和建议,为消除大型水电站厂房廊道吊物孔安全隐患、对提高安全生产和工作人员人身安全起到了积极作用。
Current situation and safety risks of the hoisting holes in the powerhouse and corridors in a large-scale hydropower station are analyzed. Considering the practical situation,reasonable renovation measures are proposed to remove the risks and improve the safety of production and the working personnel.
引文
[1]满红飞,黄锴,曾清波.三里坪水电站水工建筑物安全监测[J].人民长江,2012(s1):216-217
[2]成大先.机械设计手册[M]. 4版.北京:化学工业出版社,2004
[3]韩普昌,张红伟.一种安装于吊物孔底部上方的吸能抽屉式安全防护装置:201720787237. 8[P],2018-01-02