摘要
以某煤矿主井井塔工程为例,对该井塔的结构外观质量与结构混凝土强度进行了现场检测,并对井塔结构的抗震性进行了鉴定,依据鉴定结果,提出了抗震加固措施,使结构抗震体系更加合理完善。
Taking the main shaft tower engineering of the coal mine as an example,the paper detects the shaft tower appearance quality and the structural concrete strength in the field,identifies the seismic resistance of the shaft tower structure,and puts forward seismic resistance strengthening measures according to the identification results,so as to further perfect the structural seismic resistance system.
引文
[1]GB/T 50344-2004,建筑结构检测技术标准[S].
[2]GB 50007-2002,建筑地基基础设计规范[S].
[3]GB 50010-2010,混凝土结构设计规范[S].
[4]GBJ 117-88,工业构筑物抗震鉴定标准[S].
[5]GB 50191-93,构筑物抗震设计规范[S].
[6]GB 50011-2010,建筑抗震设计规范[S].
[7]GB 50204-2002,混凝土结构工程施工质量验收规范(2011版)[S].