摘要
抗氧化性能是纳滤膜的重要性能之一,影响纳滤膜的应用和分离成本。文章通过截留率变化率和水通量变化率来表示纳滤膜抗氧化性能,并应用统计学理论和测量不确定度评定要求对抗氧化性能测试结果的不确定度来源进行了分析,评定了测试结果的不确定度,分析了各不确定度分量对总不确定度的影响。纳滤膜抗氧化性能测试结果表示为ΔR=-9. 43%±1. 28%,k=2;ΔF=-14. 31%±0. 93%,k=2。
The oxidation resistance is one the most important characterization parameters of nanofiltration membrane,which impacts the separation cost and application of NF membrane. In this article,the oxidation resistance performance is expressed by the change rate of rejection and water flux. The sources of uncertainty in the test results of oxidation resistance were analyzed by applying statistical theory and evaluation requirements of uncertainty. The uncertainty of the oxidation resistance performance was assessed and the influence of each uncertainty component on the total uncertainty was analyzed. The test results of oxidation resistance of NF membrane were expressed asΔR =-9. 43% ± 1. 28%,k = 2; ΔF =-14. 31% ± 0. 93%,k = 2.
引文
[1] Yong-Jian Tang,Zhen-Liang Xu,et al. A chlorine-tolerant nanofiltration membrane prepared by the mixed diamine monomers of PIP and BHTTM[J]. Journal of Membrane Science,2016,(498):374-384.
[2] Takuji Shintani,Hideto Matsuyama,Naoki Kurata,et al. Development of a Chlorine-Resistant Polyamide Nanofiltration Membrane and Its Field-Test Results[J]. Journal of Applied Polymer Science2007,106(6):4 174-4 179.
[3]Tao Jie,He Ping,Xia Minling,et al. Study on the Oxidation Resistance of Thin-Film Composite Aromatic Polyamide Reverse Osmosis Membrane[J]. Technology of Water Treatment,2010,36(3):42-45.
[4] Xi Quan Cheng,Yuyan Liu,Zhanhu Guo,et al. Nanofiltration membrane achieving dual resistance to fouling and chlorine for“green”separation of antibiotics[J]. Journal of Membrane Science,2015(493):156-166.
[5]Yong Jian Tang,Lan Jie Wang,Zhen Liang Xu,et al. Novelhighflux thin film composite nanofiltration membranes fabricated by the Na ClO pre-oxidation of the mixed diamine monomers of PIP and BHTTM in the aqueous phase solution[J]. Journal of Membrane Science,2016,(502):106-115.
[6]JJF 1059-2012,测量不确定度评定与表示[S].
[7]GB/T 34242-2017,纳滤膜测试方法[S].
[8]J. M. K. Timmer,H. C. van der Horst,T. Robbertsen,Transport of lactic acid through reverse osmosis and nanofiltration membranes[J]. Journal of Membrane Science,1993(85)2:205-216.