二维多丝室探测器读出方法的优化
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Readout method for two-dimensional multi-wire proportional chamber
  • 作者:温志文 ; 祁辉荣 ; 王艳凤 ; 孙志嘉 ; 张余炼 ; 王海云 ; 张建 ; 欧阳群 ; 陈元柏 ; 李玉红
  • 英文作者:Wen Zhi-Wen;Qi Hui-Rong;Wang Yan-Feng;Sun Zhi-Jia;Zhang Yu-Lian;Wang Hai-Yun;Zhang Jian;Ouyang Qun;Chen Yuan-Bo;Li Yu-Hong;School of Nuclear Science and Technology,University of Lanzhou;State Key Laboratory of Particle Detection and Electronics;Institute of High Energy Physics,Chinese Academy of Sciences;University of Chinese Academy of Sciences;
  • 关键词:二维多丝室 ; 重心读出方法 ; 数字读出方法 ; 位置分辨
  • 英文关键词:two-dimension multi-wire proportional chamber;;center of gravity readout method;;digital readout method;;position resolution
  • 中文刊名:WLXB
  • 英文刊名:Acta Physica Sinica
  • 机构:兰州大学核科学与技术学院;核探测与核电子学国家重点实验室;中国科学院高能物理研究所;中国科学院大学;
  • 出版日期:2017-03-08 14:47
  • 出版单位:物理学报
  • 年:2017
  • 期:v.66
  • 基金:国家自然科学基金(批准号:11675197,11275224);国家自然科学基金青年基金(批准号:11305187)资助的课题~~
  • 语种:中文;
  • 页:WLXB201707023
  • 页数:9
  • CN:07
  • ISSN:11-1958/O4
  • 分类号:293-301
摘要
中国散裂中子源将建设一台基于~3He气体的二维多丝室,作为多功能反射谱仪束线的中子探测器.基于已有的研究,为优化选择二维多丝室探测器的丝结构,本文研究了三种不同的丝结构,并采用重心读出方法和数字读出方法进行了探测器的性能测量,得到了满足多功能反射谱仪探测器需求的读出方法.实验结果表明:对同种丝结构的二维多丝室探测器,重心读出方法的位置分辨和成像性能都好于数字读出方法;基于重心法读出的多丝室探测器位置分辨率可以达到约160μm,基于数字读出方法的多丝室探测器位置分辨率可以达到约400μm.优化设计的丝结构为:基于重心读出法的阳极丝间距1.5 mm、读出通道间距4 mm,基于数字读出法的阳极丝间距1.5 mm、读出通道间距2 mm.优化设计的丝结构均能满足谱仪的位置分辨要求.
        A two-dimensional multi-wire proportional chamber detector based on~3He gas is developed for meeting the multifunctional reflection spectrum detection requirements of China Spallation Neutron Source(CSNS). Based on the previous researches in our laboratory, three different wire structures are studied for optimizing the wire readout structure of the two-dimensional multi-wire proportional chamber detector, and the performances of the detectors are measured by two readout methods: the center of gravity readout method and the digital readout method in this paper. The selected method could satisfy the requirement of multifunctional reflection spectrum instrument. Finally, the results indicate that the position resolution and the imaging capability obtained by using the center of gravity readout method should be better than by using the digital readout method. The position resolution could reach to about 160 μm by using the center of gravity readout method. While the position resolution of the detector could be obtained to be about 400 μm by using the digital readout method. Re-designed and compared with each other are the three different wire structures:1.5 mm of the anode wire pitch and 4 mm of the readout strip pitch with the center of gravity readout method, 1.5 mm of the anode wire pitch and 2 mm of the readout strip pitch with the digital readout method. Both of the optimized designs of the wire structure could meet the requirement of the position resolution for the reflection spectrum device.
引文
[1]Orban J,Cser L,Rosta L,T?r?k Gy,Nagy A 2011NIMA 632 124
    [2]Li X L,Zhang Y L,Qian H,Xu Z Z,Wang X L 2008Chin.Phys.C 36 519
    [3]Radeka V,Boie R A 1980 Nuclear Instruments and Methods 178 543
    [4]Fonte P 1994 NIMA 348 338
    [5]Sitar B,Stubbs R J,Breare J M 1976 Nuclear Instruments and Methods 134 267
    [6]Tian L C,Sun Z J,Qi H R,Tang B,LüX Y,Chen Y B,Ouyang Q 2013 Nucl.Phys.Rev.30 42
    [7]Wang X H 2009 Ph.D.Dissertation(Beijing:University of Chinese Academy of Sciences)(in Chinese)[王小胡2009博士学位论文(北京:中国科学院大学)]