摘要
过程仪表校验仪是常见的工业现场设备。针对校准过程中,模拟热电偶输出功能测量超差的某一台过程仪表校验仪设备,文章依据校准规范采用了两种方法完成校准。文章通过对两种方法的比对和研究,得出了可靠的校准结论。
Process calibrator is a common industrial field equipment. In view of a certain process instrument calibrator equipment which simulates the output function of thermocouple to measure the super error in the process of calibration, this paper adopts two methods to complete the calibration according to the calibration specification. In this paper, through the comparison and study of the two methods, a reliable conclusion concerning calibration is obtained.
引文
[1]陈旭,孙力,凌彦萃.温度校准仪热电偶档基于冷端补偿的校准方法研究[J].中国测试,2018,44(12):96-100.
[2]陈永强,崔馨元,吴勤,等.热电偶校准过程中的不同冷端补偿方法的比较[J].计量与测试技术,2018,45(05):68-69.
[3]司延召.过程校验仪热电偶功能校准方法分析[J].计量与测试技术,2017,44(02):73-75+77.