330MW机组低压旁路阀内漏原因分析及防范措施
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Reason Analysis and Preventive Measures of the Inner Leakage Low-pressure bypass-valve of 330MW Unit
  • 作者:孙曙
  • 英文作者:SUN Shu;North China Electric Power, Jiangsu Province Yangzhou Generation Co.Ltd.;
  • 关键词:低旁系统 ; 低压旁路阀 ; 损伤 ; 工艺措施
  • 英文关键词:Low side system;;Low pressure bypass-valve;;Damage;;Technological measures
  • 中文刊名:HELJ
  • 英文刊名:Heilongjiang Science
  • 机构:江苏华电扬州发电有限公司;
  • 出版日期:2015-09-15
  • 出版单位:黑龙江科学
  • 年:2015
  • 期:v.6
  • 语种:中文;
  • 页:HELJ201509049
  • 页数:2
  • CN:09
  • ISSN:23-1560/G3
  • 分类号:102-103
摘要
我公司两台330MW机组采用高压旁路(主蒸汽)和低压旁路(再热蒸汽)二级串联旁路装置。低压旁路蒸汽变换阀多次出现阀芯裂纹、吹损、机械损伤等情况,本文对阀门状况进行分析、归纳总结,以便为今后的低压旁路阀检修工作中消除缺陷提供一些帮助。
        Our company is two 330 MW units with high pressure bypass(main steam) and low pressure bypass(steam) two series connected by series. Low pressure bypass steam valve has occurred many times in the valve core crack, blowing loss,mechanical damage, etc.,this paper analyzes the status of the valve,summarized in order to provide some help for the future of the low pressure bypass valve repair work to eliminate defects.
引文
[1]江苏华电扬州发电有限公司.330MW机组汽轮机检修规程[K].
    [2]上海电站辅机厂.《350t/h电动两级串联旁路系统》安装使用说明书[K].