摘要
为了解决北方农村的清洁供暖问题,自行设计了一种适于北方广大农村住宅制冷和制热的直接蒸发式地源热泵分体式空调机组,将各部分集成,并通过可变温度热源对机组进行了测试,测试结果显示在满足冬季室内温度18℃的条件下,低温热源的温度达6℃机组能效比EER能达到4.0及以上,在典型农户实际应用整个供暖季的费用约为1500元,能够在农村地区推广应用。
In order to solve the problem of clean heating in rural areas of northern China, we designed a direct evaporative ground source heat pump split air conditioning unit suitable for refrigeration and heating of rural houses. Each part is integrated, and the unit is tested by variable temperature heat source. The test results show that under the condition of 18℃ indoor temperature in winter, the energy efficiency ratio EER of the unit with low temperature heat source up to 6℃ can reach 4.0 or above. The cost of the whole heating season is about 1,500 yuan, which can be popularized and applied in rural areas.
引文
[1]郭永辉,侯根富,李兴友.直接膨胀式地源热泵设计工况探讨[J].福建工程学院学报,2013,11(6):556-560.
[2]王勇,龙恩深,韦强,等.地源热泵地下管群换热器设计施工技术点滴[J].暖通空调,2004,34(11):118-121.
[3]雷开先.节能地温空调(地源热泵)系统及在成都地区发展环境分析[J].四川建材,2012(2):265-267.
[4]郭学军.煤矿空压机废热回收系统研究[J].装备制造技术,2013(4).