降低高速公路建筑场区电锅炉供暖运行费用分析
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Analysis on reducing operation cost of electric boiler heating in expressway service area
  • 作者:刘志强
  • 英文作者:Liu Zhiqiang;The Communications Planning Surveying and Designing Institute of Shanxi Province;
  • 关键词:电锅炉 ; 供暖方式 ; 蓄热
  • 英文关键词:electric boiler;;heating methods;;thermal storage
  • 中文刊名:JZSX
  • 英文刊名:Shanxi Architecture
  • 机构:山西省交通规划勘察设计院;
  • 出版日期:2019-01-20
  • 出版单位:山西建筑
  • 年:2019
  • 期:v.45
  • 语种:中文;
  • 页:JZSX201903067
  • 页数:2
  • CN:03
  • ISSN:14-1279/TU
  • 分类号:135-136
摘要
采用电锅炉供暖运行费用高居不下,为了降低高速公路服务场区的运营成本,经过调研、对比分析,得出降低电锅炉运行费用的较佳方案——增设蓄热水箱。并且通过实际投入运行的供暖场区来看,电锅炉加蓄热水箱的供暖方式,热舒适度高,运行费用低,经济效益和社会效益显著,具有较高的推广应用价值。
        Electric boiler heating operation costs remain high,in order to reduce the operating costs of expressway service area,through research and comparative analysis,the better plan to reduce the operating costs of electric boiler-adding hot water storage tank. According to the feedback,the heating mode of electric boiler with hot water storage tank has the advantages of high thermal comfort,low operating cost,remarkable economic and social benefits,and popularization and application value is high.
引文
[1]陆耀庆.实用供热空调技术手册[M].北京:中国建筑工业出版社,1996.
    [2]中国建筑标准设计研究院.全国民用建筑工程设计技术措施节能专篇·暖通空调(动力分册)[M].北京:中国计划出版社,2007.
    [3]任卫英.提高高速公路野外建筑供暖效益分析[J].山西建筑,2017,43(33):133-134.