Locator附着体种植覆盖义齿的临床应用
详细信息    查看全文 | 推荐本文 |
  • 作者:斯露婕 ; 傅柏平
  • 关键词:种植覆盖义齿 ; Locator附着体 ; 综述
  • 中文刊名:ZJYE
  • 英文刊名:Zhejiang Medical Journal
  • 机构:浙江大学医学院附属口腔医院修复科;
  • 出版日期:2019-05-30
  • 出版单位:浙江医学
  • 年:2019
  • 期:v.41
  • 语种:中文;
  • 页:ZJYE201910039
  • 页数:5
  • CN:10
  • ISSN:33-1109/R
  • 分类号:121-124+141
摘要
随着口腔种植学以及修复学的不断发展,近十余年来,种植覆盖义齿被广泛应用于无牙颌的修复,常用的附着体包括球帽式附着体、杆卡式附着体、弹性附着体、磁性附着体等。其中Locator作为一种弹性附着体,具有技术门槛低,加工工艺简单,便于维护等优点。对于无牙颌患者,一般单颌植入2~4枚种植体即可使用Locator附着体达到良好的修复效果,其临床应用的优越性也得到了体外及临床实验结果的肯定。本文就Locator附着体种植覆盖义齿的临床应用作一综述。
        
引文
[1]刘宝林.口腔种植学[M].北京:人民卫生出版社,2011:272-290.
    [2]Lee DJ.Performance of attachments used in implant-supported overdentures:review of trends in the literature[J].Journal of Periodontal&Implant Science,2013,43(1):12-17.
    [3]Krishnaraj R,Murugan R,Meera NK,et al.Implant-based overdenture:A review in patient perspective[J].Journal of Pharmacy&Bioallied Sciences,2016,8(Suppl 1):S20-S22.
    [4]Sia PKS,Masri R,Driscoll CF,et al.Effect of locator abutment height on the retentive values of pink locator attachments:An in vitro study[J].Journal of Prosthetic Dentistry,2017,117(2):283-288.
    [5]Patzelt,Sebastian BM.Summary of:Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures[J].BDJ,2014,216(3):134-135.
    [6]Chung KH,Chung CY,Cagna DR,et al.Retention characteristics of attachment systems for implant overdentures[J].Journal of Prosthodontics Official Journal of the American College of Prosthodontists,2010,13(4):221-226.
    [7]Rutkunas V,Mizutani H,Takahashi H,et al.Wear simulation effects on overdenture stud attachments[J].Dental Materials Journal,2011,30(6):845-853.
    [8]Evtimovska E,Masri R,Driscoll CF,et al.The change in retentive values of locator attachments and hader clips over time[J].Journal of Prosthodontics,2010,18(6):479-483.
    [9]Boulos PJ,Akiki LA,MakzouméJE,et al.Retentive force variations of stud attachments for implant overdentures[J].General Dentistry,2018,66(4):41-45.
    [10]Daou EE.Biomaterial aspects:A key factor in the longevity of implant overdenture attachment systems[J].Journal of International Society of Preventive&Community Dentistry,2015,5(4):255-262.
    [11]Jin SY,Kwon KR,Noh K,et al.Stress analysis of mandibular implant overdenture with locator and bar/clip attachment:Comparative study with differences in the denture base length[J].Journal of Advanced Prosthodontics,2017,9(3):143-151.
    [12]Takahashi T,Gonda T,Tomita A,et al.Effect of Attachment Type on Implant Strain inMaxillary Implant Overdentures:Comparison of Ball,Locator,and Magnet Attachments.Part 2:Palateless Dentures[J].International Journal of Oral&Maxillofacial Implants,2018,33(2):357-364.
    [13]Cakarer S,Can T,Yaltirik M,et al.Complications associated with the ball,bar and Locator attachments for implant-supported overdentures[J].Med Oral Patol Oral Cir Bucal,2011,16(7):953-959.
    [14]Troeltzsch M,Troeltzsch V,Brodine AH,et al.Clinical Performance and Peri-implant Parameters of 132 Implants Supporting Locator-Retained Overdentures:A Case Series of 33 Patients[J].International Journal of Oral&Maxillofacial Implants,2013,28(4):1132-1139.
    [15]庄润涛,耿威,李钧,等.球帽和Locator附着体种植覆盖义齿的临床疗效评价[J].实用口腔医学杂志,2017,33(4):541-545.
    [16]Ha-Young K,Jeong-Yol L,Sang-Wan S,et al.Attachment systems for mandibular implant overdentures:a systematic review[J].Journal of Advanced Prosthodontics,2012,4(4):197-203.
    [17]Lee DJ.Performance of attachments used in implant-supported overdentures:review of trends in the literature[J].Journal of Periodontal&Implant Science,2013,43(1):12-17.
    [18]Wilfried K,Kleis MD,Ka mmerer PW,et al.A Comparison of Three DifferentAttachment Systems forMandibular Two-Implant Overdentures:One-Year Report[J].Clinical Implant Dentistry&Related Research,2010,12(3):209-218.
    [19]Mackie A,Lyons K,Thomson WM,et al.Mandibular two-implant overdentures:three-year prosthodontic maintenance using the locator attachment system[J].International Journal of Prosthodontics,2011,24(4):328-331.
    [20]Heydecke G,Penrod JR,Takanashi Y,et al.Cost-effectiveness of mandibular two-implant overdentures and conventional dentures in the edentulous elderly[J].Journal of Dental Research,2005,84(9):794-799.
    [21]El-Sheikh AM,Shihabuddin OF,Ghoraba SMF.Two Versus Three Narrow-Diameter Implants with Locator Attachments Supporting Mandibular Overdentures:A Two-Year Prospective Study[J].International Journal of Dentistry,2012,2012:1-7.
    [22]Karbach J,Hartmann S,Jahn-Eimermacher A,et al.Oral Health-Related Quality of Life in Edentulous Patients with Two-vs Four-Locator-Retained Mandibular Overdentures:A Prospective,Randomized,Crossover Study[J].International Journal of Oral&Maxillofacial Implants,2015,30(5):1143-1148.
    [23]Liu J,Pan S,Dong J,et al.Influence of implant number on the biomechanical behavior of mandibular implant-retained/supportedoverdendure:A three-dimensional finite element analysis[J].Journal of Dentistry,2013,41(3):241-249.
    [24]Alsabeeha NH,Swain MV,Payne AG.Clinical performance and material properties of single-implant overdenture attachment systems[J].International Journal of Prosthodontics,2011,24(3):247-254.
    [25]Elsyad MA,Maryod WH,Mostafa AZ.Effect of Implant Position on Clinical and Radiographic Outcomes of Locator-Retained Mandibular Overdentures:A 1-Year Prospective Study[J].Journal of Prosthodontics,2019,28(2):e699-e704.
    [26]Alvarezarenal A,Gonzalezgonzalez I,Dellanoslanchares H,et al.Influence of implant positions and occlusal forces on peri-implant bone stress in mandibular two-implant overdentures:a 3d finite element analysis[J].Journal of Oral Implantology,2017,43(6):419-428.
    [27]Nguyen CTMR,Driscoll CF,Romberg E.The effect of denture cleansing solutions on the retention of pink Locator Attachments:an in vitro study[J].J.Prosthodont,2010,19(3):226-230.
    [28]Kurtulus IL,Gurbulak AG.The In Vitro comparison of the retention of an implant-supported stud attachment locator and straumann ball attachment at different angulations[J].Nigerian journal of clinical practice,2018,21(5):639-644.
    [29]Elsyad MA,Emera RM,Ashmawy TM.Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used forMandibular Overdentures:An In Vitro Study[J].Journal of Prosthodontics,2019,28(2):e666-e674.
    [30]Offord D,Mathieson G,Kingsford N,et al.Peri-implant health,clinical outcome and patient-centred outcomes of implantsupported overdentures in the mandible and the maxilla[J].BDJ Open,2017,17(3):17017.
    [31]Al-Dharrab A.Three-year Prospective Evaluation of Immediately Loaded Mandibular Implant Overdentures retained with Locator Attachments[J].JournalofContemporaryDentalPractice,2017,18(9):842-850.
    [32]Schincaglia G,Rubin S,Thacker S,et al.Marginal Bone ResponseAround Immediate-andDelayed-Loading Implants Supporting a Locator-Retained Mandibular Overdenture:A Randomized Controlled Study[J].The International Journal of Oral&Maxillofacial Implants,2016(3):448-458.
    [33]Aeran H,Seth J,Sharma G.Occlusion in Implantology-A Key to Longevity[J].Guident,2015(9):16-19.
    [34]Rilo B,JoséLuis da Silva,Maria Jesús Mora,et al.Guidelines for occlusion strategy in implant-borne prostheses.A review[J].International Dental Journal,2008,58(3):139-145.
    [35]Ismail HA,Yousief SA,Mahrous AI,et al.Clinical and Radiographic Evaluation of Median Lingualized Occlusion in Implant Retained Mandibular Complete Overdenture[J].Journal of International Oral Health,2015,7(Suppl 1):5-8.
    [36]Chang HS,Hsieh YD,Hsu ML.Long-term survival rate of implant-supported overdentures with various attachment systems:A 20-year retrospective study[J].Journal of Dental Sciences,2015,10(1):55-60.
    [37]Tehini G,Baba NZ,Berberi A,et al.Effect of SimulatedMastication on the Retention of Locator Attachments for Implant-Supported Overdentures:An In Vitro Pilot Study[J].Journal of Prosthodontics Official Journal of the American College of Prosthodontists,2017.DOI:10.1111/jopr.12670.[Epub ahead of print]
    [38]Besimo CE,Guarneri A.In vitro,retention force changes of prefabricated attachments for overdentures[J].Journal of Oral Rehabilitation,2010,30(7):671-678.
    [39]Isin Ku rkcu og lu,Serhat E ozkir,Aysegu l Ko rog lu,et al.Effect of denture cleansing solutions on different retentive attachments[J].Journal of Prosthetic Dentistry,2016,115(5):606-610.
    [40]Vere J,Hall D,Patel R,et al.Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system[J].International Journal of Prosthodontics,2016,25(4):392-401.
    [41]Meijer HJA,Raghoebar GM,De Waal YCM,et al.Incidence of peri-implant mucositis and peri-implantitis in edentulous patients with an implant-retained mandibular overdenture during a 10-year follow-up period[J].Journal of Clinical Periodontology,2014,41(12):1178-1183.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700