贯流式水轮发电机空冷器爆管漏水分析与处理
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Analysis and Treatment of Broken Pipe and Water Leakage of Air Cooler in Tubular Turbine Generator
  • 作者:李凌
  • 英文作者:LI Ling;Guangxi Wuzhou Guijiang Electric Power Co.,Ltd.;
  • 关键词:膨胀水箱 ; 空冷器 ; 漏水
  • 英文关键词:expansion tank;;air cooler;;water leakage
  • 中文刊名:GXDL
  • 英文刊名:Guangxi Electric Power
  • 机构:广西梧州桂江电力有限公司;
  • 出版日期:2018-04-28
  • 出版单位:广西电力
  • 年:2018
  • 期:v.41;No.171
  • 语种:中文;
  • 页:GXDL201802022
  • 页数:2
  • CN:02
  • ISSN:45-1307/TK
  • 分类号:81-82
摘要
京南电厂1号贯流式水轮发电机在投运早期,由于冷却水质不合格,对空冷器铜管造成腐蚀,此外,冷却水系统膨胀水箱气囊破裂损坏造成冷却水压不稳定,从而导致2号空冷器铜管漏水。更换膨胀水箱和采用环氧树脂封堵空冷器开裂铜管后,漏水现象消除,系统水压调节正常,满足机组安全运行需要。
        The copper tube of air cooler had been corroded because of the disqualification of cooling water quality in the early operation stage of Jingnan No.1 tubular turbine generation. Besides, the damage of air bag of expansion tank in water cooling system caused the unstable cooling water pressure, which caused the water leakage of cooper tube of No.2 air cooler. After the replacement of expansion tank and the block of cracked cooper tube of the air cooler by epoxy resins, the water leakage has been eliminated and the regulation of system water pressure are normal, which satisfy the security operation of generator unit.
引文
[1]GEA公司.空冷器使用维护说明书[Z].德国:GEA公司,1995.
    [2]贝斯特国际公司.膨胀罐的原理功能和安装维护[Z].上海:贝斯特国际公司,2016.
    [3]GB/T8564—2003,水轮发电机组安装技术规范[S].
    [4]NB/T47007—2010,空冷式热交换器[S].