摘要
静态标定后的电子测压器靶场实测时存在测不准和测试精度不高的问题,为了提高系统的可靠性和测试精度,提出了基于模拟膛压发生器的模拟应用环境的准静态校准方法。为了提高校准工作效率,提出了基于多传感器数据融合的准静态校准数据处理方法。文中详细论述了多传感器数据融合理论以及标准压力曲线上升沿校准法的合理性。用上述方法校准后的电子测压器进行靶场实测,测试数据精度高,可靠性强。
After the static calibration,the test result of electronic pressure measuring device has the problem of inaccuracy and low precision. In order to improve the reliability and measuring accuracy of system,come up with quasistatic calibration method of simulated application environment based on simulation chamber pressure deviser. With the purpose of increase calibration work efficiency,put forward quasi-static calibration data processing method based on multi-sensor data fusion. The article detailedly discussed multi-sensor data fusion theory and the rationality of standard pressure curve rising edge calibration method. Electronic pressure measuring device which has been calibrated using the above method was tested in shooting range,and the data has high reliability and high precision.
引文
[1]孙正席,张瑜,裴东兴.微型电子测压器准动态校准的合理性[J].传感技术学报,2012,25(11):1522-1526.
[2]杨文,张瑜,祖静.放入式电子测压器的校准技术研究[J].传感技术学报,2015,28(9):1384-1388.
[3]凤宝利,刘琴,席海军,等.小体积膛压测试仪及其校准方法[J].计量与测试技术,2013,40(7):33-35.
[4]张瑜,祖静,张红艳,等.基于环境因子的火炮膛压测试仪校准装置[J].探测与控制学报,2012,34(6):35-39.
[5]中国人民解放军总装备部测量通信总体研究所.GJB 2973A—2008火炮内弹道测试方法[S].北京:总装备部军标出版发行部,2008.
[6]张延龙,王俊勇.多传感器数据融合技术概述[J].舰船电子工程,2013,33(2):41-44.
[7]王凤朝,黄树采,韩朝超.多传感器信息融合及其新技术研究[J].航空计算技术,2009,39(1):102-106.
[8]杨斌.正态性检验的几种方法比较[J].统计与决策,2015(14):72-74.
[9]田禹.基于偏度和峰度的正态性检验[D].上海:上海交通大学,2012.
[10]袁月华,裴东兴,张瑜,等.基于相关性的微型电子测压器模拟应用环境下的校准方法[J].弹箭与制导学报,2011,31(6):197-198.
[11]王卿.放入式电子测压器的智能化设计及校准技术研究[D].太原:中北大学,2011.
[12]梁高翔,马铁华,张艳兵.相关性校准法上升沿抽点和线性关系的合理性[J].探测与控制学报,2011,33(4):77-80.