Multi-matrix opto-electronic system for measuring deformation of the millimeter range radiotelescope elements
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Multi-matrix opto-electronic system for measuring deformation of the millimeter range radiotelescope elements
  • 作者:黎人溥 ; Konyakhin ; Igor ; Tong ; Minh ; Hoa ; 周敏
  • 英文作者:LI Ren-pu;Konyakhin Igor;Tong Minh Hoa;ZHOU Min;Chongqing Engineering Research Center of Intelligent Sensing Technology and Microsystem, Chongqing University of Post and Telecommunications;Faculty of Applied Optic, ITMO University;
  • 中文刊名:OELJ
  • 英文刊名:光电子快报(英文版)
  • 机构:Chongqing Engineering Research Center of Intelligent Sensing Technology and Microsystem, Chongqing University of Post and Telecommunications;Faculty of Applied Optic, ITMO University;
  • 出版日期:2019-03-01
  • 出版单位:Optoelectronics Letters
  • 年:2019
  • 期:v.15;No.83
  • 基金:supported by the National Key R&D Program of China(Nos.2018YFF01010202 and 2018YFF01010201);; the National Natural Science Foundation of China(Nos.61705027 and 11704053);; the Innovation Leader Talent Project of Chongqing Science and Technology(No.CSTC-CXLJRC201711);; the Basic Research Project of Chongqing Science and Technology Commission(Nos.CSTC-2017csmsA40017,CSTC-2015jcy-BX0068 and CSTC-2018jcyjax0619);; the Science and Technology Project Affiliated to the Education Department of Chongqing Municipality(Nos.KJZH17115,KJQN201800626,KJ1704104 and KJ1704106)
  • 语种:英文;
  • 页:OELJ201902016
  • 页数:3
  • CN:02
  • ISSN:12-1370/TN
  • 分类号:70-72
摘要
A novel optical instrument is proposed and studied to measure the deformation of each connection point for a mirror, which includes 24 multi-matrix base units and can be used in millimeter-scale signal reflection systems.Experimental investigations reveal that the error of measurement is σ=8.7×10~(-3) mm at a distance of 5 500 mm, which allows to measure the linear deformation of a radiotelescope with the mirror diameter of 70 m.
        A novel optical instrument is proposed and studied to measure the deformation of each connection point for a mirror, which includes 24 multi-matrix base units and can be used in millimeter-scale signal reflection systems.Experimental investigations reveal that the error of measurement is σ=8.7×10~(-3) mm at a distance of 5 500 mm, which allows to measure the linear deformation of a radiotelescope with the mirror diameter of 70 m.
引文
[1]Новиков М.А.and Коняхин И.А., Современные оптико-электронные системы мониторинга деформаций объектов.// Пятая Санкт-Петербургская Ассамблея молодых учёных и специалистов./Тезисы докладов.СПб: СПбГУ, С.55.(2000).
    [2]Артеменко Ю.Н., Коняхин И.А., Панков Э.Д.and Тимофеев А.Н., Изв.Вузов.Приборостроение 9, 51 (2008).
    [3]Wu B and Yang S, Laser Technol.39, 5 (2015).
    [4]Onori D., Scotti F., Scaffardi M., Bogoni A.and Laghezza F., Journal of Lightwave Technology 34, 20 (2016).
    [5]Wu H., Zhang F., Meng F., Balling P., Li J., Pan L.and Qu X., IEEE Photon.Technol.Lett.27, 24 (2015).
    [6]Wu H., Zhao T., Wang Z., Zhang K., Xue B., Li J.and Qu X., Applied Physics Letters 111, 25 (2017).
    [7]Wang G., Li S., An G., Wang X., Zhao Y.and Zhang W., Applied Optics 54, 8817 (2015).
    [8]Дрейпер Н.and Смит Г, Прикладной регрессионный анализ.пер.с англ.М.: Финансы и статистика, Изд.2-е, перераб.и доп 1, 366 (1986).

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700