摘要
对新工厂调试过程中发生的车身电泳气室问题进行了分析,并结合设备特点对气室问题进行了验证。采取改变工件电泳角度、调整电泳循环喷嘴方向、增大电泳槽液循环压力等措施,使气室问题得到了解决。
The electrophoresis bubble of BIW during new factory debugging process were analyzed. Combined with the characteristics of the equipment, the problem of the gas chamber was verified. The problem of gas chamber is solved by changing electrophoresis angle of the work pieces, adjusting the direction of electrophoresis circulation nozzles and increasing circulation pressure.