摘要
通过对某大型商业文化室内步行街防火设计变更方案的研究,分析室内步行街的结构特点、火灾危险性及消防设计难点。针对室内步行街中部区域疏散到安全区距离超长、步行街顶棚无自然通风等诸多超出规范规定的问题提出消防措施,如将室内步行街划分为亚安全区域、设置避难间及避难走道、增设机械排烟及环形消防车道等,以提高建筑的消防安全性。
Through research of change scheme of fire safety design of a large commercial and cultural indoor pedestrian street,the structural characteristic,fire risks and difficulties in fire design were analyzed.To improve the fire safety of building,the countermeasures were proposed about overlong evacuation distance from middle of indoor pedestrian street to safety evacuation and lack of natural ventilation on pedestrian street ceiling,including defining indoor pedestrian street as sub-safety area,setting of fire cut and evacuation refuge walkway and adding mechanical smoke exhaust and annular fire lane.
引文
[1]杨淑江,倪天晓,张新.大型商业室内步行街性能化消防设计[J].消防科学与技术,2012,31(4):370-374.
[2]赵泽文.某商业综合体室内步行街消防设计数值模拟[J].消防科学与技术,2012,31(8):816-820.
[3]冯俊峰,蔡海宇.大型商业综合体室内步行街消防设计分析与探讨[J].武警学院学报,2015,31(4):61-64.
[4]孙旋.有顶棚商业步行街消防设计[J].中国消防,2015,(15):32-33.
[5]刘松涛,卫文彬,欧宸.大型商业综合体中庭步行街消防设计研究[J].消防科学与技术,2015,34(8):1024-1027.
[6]刘武涛.有顶商业步行街消防设计例析[J].建筑,2015,(18):84-85.
[7]张涛,张静波.某人防步行街消防性能化设计[J].山西建筑,2014,40(12):12-13.
[8]GB 50016-2014,建筑设计防火规范[S].