摘要
采用溶剂热法制备了磁性金属有机骨架吸附剂Fe_3O_4-NH_2@MIL-101,通过电子显微镜、红外光谱、X射线衍射对吸附剂的形貌和组成进行了表征,磁强计对吸附剂的磁强度进行了测定。使用该吸附剂进行磁固相萃取,结合高效液相色谱-紫外检测,对农田灌溉水中4种苯甲酰脲类杀虫剂(氯吡脲、氟幼脲、氟铃脲和虱螨脲)进行分析。实验对吸附和洗脱条件进行了优化,包括吸附剂用量、吸附时间、pH值、离子强度、洗脱溶剂种类以及洗脱时间和体积。在最佳实验条件下,方法能够有效富集灌溉水中的苯甲酰脲类杀虫剂。4种苯甲酰脲类杀虫剂在0. 010~3. 0 mg/L浓度范围内线性关系良好,相关系数(r)均大于0. 999 5,检出限为0. 03~0. 09μg/L,定量下限为0. 10~0. 30μg/L。方法的加标回收率为81. 7%~95. 4%,RSD小于10%。该方法前处理操作简便,萃取用时不超过15 min,可用于农田灌溉水中苯甲酰脲类杀虫剂的检测。
A method of high performance liquid chromatography( HPLC) with magnetic solid-phase extraction( MSPE) was developed for the determination of four benzoylurea pesticides,i. e. forchlorfenuron,penfluron, hexaflumuron and lufenuron in irrigation water. A magnetic metal organic framework sorbent( Fe_3O_4-NH_2@MIL-101) was fabricated via solvothermal method. The composition and morpholgy of the composite were characterized by scanning electron microscopy( SEM),Fourier transform infrared spectroscopy( FT-IR) and X-ray diffraction( XRD) analysis. Meanwhile,the magnetic intensity of the material was detected with a vibrating sample magnetometer. The determination of four analytes was performed by HPLC with the synthesized composite as MSPE adsorbent.The adsorption and elution factors,including adsorbent amount,adsorption time,p H value,elution time and elution volume,were investigated. Under the optimum conditions,the calibration curves for four benzoylurea pesticides showed good linear relationships in the range of 0. 010-3. 0 mg/L with correlation coefficients( r) higher than 0. 999 5. The detection limits and the quantitation limits were in the ranges of 0. 03-0. 09 μg/L and 0. 10-0. 30 μg/L,respectively. The recoveries at three spiked levels ranged from 81. 7% to 95. 4% with RSD less than 10%. With a simple pretreatment process and an extraction time within 15 min,the method could be applied in the analysis on trace residues of benzoylurea pesticides in irrigation water.
引文
[1]Wang L Z,Zhou Y,Chen Y,Li S Y,Wang R L,Ke H X.J.Instrum.Anal.(王连珠,周昱,陈泳,李术英,王瑞龙,柯慧贤.分析测试学报),2010,29(3):289-293.
[2]Zhang Y,Chen L,Huang X J,Yuan D X.Chin.J.Anal.Chem.(张咏,陈蕾,黄晓佳,袁东星.分析化学),2015,43(9):1335-1341.
[3]Mei M,Huang X J,Liao K,Yuan D X.Anal.Chim.Acta,2015,860:29-36.
[4]Nougadère A,Reninger J C,Volatier J L,Leblanc J C.Food Chem.Toxicol.,2011,49(7):1484-1510.
[5]Liu H,Shen C Y,Zhao Z Y,Shen W J,Xu J Z,Ding T,Wu B.J.Instrum.Anal.(柳菡,沈崇钰,赵增运,沈伟建,徐锦忠,丁涛,吴斌.分析测试学报),2010,29(11):1180-1184.
[6]Wang H Z,Liu C R,Huang X D,Jia C D,Cao Y,Hu L,Lu R H,Zhang S B,Gao H X,Zhou W F,Xu D H.New J.Chem.,2018,42(11):8791-8799.
[7]Zhang J H,Li M,Yang M Y,Peng B,Li Y B,Zhou W F,Gao H X,Lu R H.J.Chromatogr.A,2012,1254:23-29.
[8]Wang X L,Ma R Y,Hao L,Wu Q H,Wang C,Wang Z.J.Chromatogr.A,2018,1551:1-9.
[9]Zhang W M,Yan Z M,Gao J,Tong P,Liu W,Zhang L.J.Chromatogr.A,2015,1400:10-18.
[10]Jiang X H,Ding W J,Luan C L,Dai J G.J.Instrum.Anal.(蒋晓华,丁文捷,栾崇林,代建国.分析测试学报),2018,37(5):556-561.
[11]Li L,Fu S G,Yuan B Y,Xie S M,Yuan L M.J.Instrum.Anal.(李丽,付仕国,袁宝燕,谢生明,袁黎明.分析测试学报),2017,36(12):1439-1444.
[12]Férey G,Mellot-Draznieks C,Serre C,Millange F,Dutour J,SurbléS,Margiolaki I.Science,2005,309(5743):2040-2042.
[13]Huang Y F,Liu M,Wang Y Q,Li Y,Zhang J M,Huo S H.RSC Adv.,2016,6(19):15362-15369.
[14]Liu S Z,Zhao F L,Guo Q,Cui B C.Chem.Ind.Eng.Prog.(刘淑芝,赵福临,郭齐,崔宝臣.化工进展),2017,36(3):918-925.
[15]Huang Y F,Wang Y Q,Zhao Q S,Zhang J M.RSC Adv.,2014,4(89):47921-47924.
[16]Wang C H,Ma X X,Wang C,Wu Q H,Wang Z.Chin.Chem.Lett.,2014,25(12):1625-1629.