摘要
采用火试金富集得到贵金属合粒,经王水溶解,在王水(10%)介质下采用全谱直读电感耦合等离子体发射光谱(ICP-OES)法测定分银渣中铂、钯的含量。方法精密度好,准确度高,铂、钯的加标回收率在98.4%~102%,可以很好地满足分银渣中铂、钯含量的测定。
Sub-silver residue is the main by-product of copper anode mud electrolysis which contains a measureable amount of noble metals of platinum and palladium.In this study,a method based on ICP-OES was described for rapid and accurate determination of platinum and palladium content in sub-silver samples.Fire assay preconcentration was used to obtain composite granule which were dissolved in 10%aqua-regia for sample preparation.The described method showed good precision and high accuracy with recovery rate ranged from 98.4%to 102%,and can be widely utilized for platinum and palladium content measurement in sub-silver residue.
引文
[1]李义兵,陈白珍,龚竹青.分银渣中贵金属的提取[J].有色金属(冶炼部分)[Nonferrous Metals(Extractive Metallurgy)],2002(6):32-34.
[2]郭学益,肖彩梅,钟菊芽,等.铜阳极泥处理过程中贵金属的行为[J].中国有色金属学报(The Chinese Journal of Nonferrous Metals),2010,20(5):990-998.
[3]曾妙先.火试金在贵金属元素分析中的应用[J].黄金(Gold),2003(5):48-50.
[4]李华昌,屈太原,何飞顶.贵金属元素分离富集技术进展[J].中国无机分析化学(Chinese Journal of Inorganic Analytical Chemistry),2011,1(1):7-12.
[5]韩晓.电感耦合等离子体发射光谱(ICP-OES)法测定铅精矿中9种元素[J].中国无机分析化学(Chinese Journal of Inorganic Analytical Chemistry),2016,6(4):33-37.
[6]赵伟,尤雅婷,徐松,等.火试金富集-电感耦合等离子体质谱法测定铜精矿中金铂钯[J].冶金分析(Metallurgical Analysis),2011,31(10):41-45.
[7]马丽.电感耦合等离子体原子发射光谱(ICP-AES)法测定锡铅焊料中11种微量元素[J].中国无机分析化学(Chinese Journal of Inorganic Analytical Chemistry),2017,7(3):51-54.