LTB245E1型断路器为220 kV SF_6断路器,配置BLK222型弹簧操动机构,目前广泛应用于四川电网中。通过对一起该型断路器弹簧机构缺陷原因的分析,就LTB245E1-BLK222型断路器检修工作重点及对策进行了探讨,以预防电气故障的发生。
LTB245 E1 circuit breaker is a widely used switch equipment in electric power enterprises currently. It is the 220 kV SF_6 circuit breaker produced by Beijing ABB Company, which is equipped with BLK222 spring operating mechanism. A typical fault of spring operating mechanism is analyzed. In order to prevent the electrical faults, the focus of the repair work and countermeasures are discussed.
引文
[1] 张成林.高压断路器状态检修系统研究[D].广州:华南理工大学,2007.
[2] 许婧,王晶,高峰, 等.电力设备状态检修技术研究综述[J].电网技术,2000,24(8):48-52.
[3] 孙兵.LTB245E1型断路器BLK222型弹簧机构的故障分析和预防[J].价值工程,2013(1):68-70.
[4] 崔景春,袁大陆,杜彦明.SF6断路器操动机构的运行可靠性和选型探讨[J].高压电器,2001,37(2):1-4.
[5] 方可行.SF6断路器的弹簧操动机构及其应用[J].高压电器,2003,39(6):76-77.
[6] 邓瑞鹏.BLK222型弹簧机构故障分析及研究[J].电力系统装备,2018(1):145-146.
[7] 熊胜源,邱偈,刘涛.BLK222型弹簧机构故障分析及研究[J].山西电力,2017(5):51-54.
[8] 唐跃林,伍平,谢林涛, 等.一台252 kV SF6断路器合闸故障分析及处理[J].高压电器,2011,47(2):72-75.