以ZIF-8为固相微萃取涂层分析环境水样中痕量多溴联苯醚
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Analysis of Polybrominated Diphenyl Ethers in Environmental Water Samples Using Zeolitic Imidazolate Framework-8 as Solid Phase Microextraction Coating
  • 作者:李振 ; 周家斌 ; 王霞 ; 赵汝松
  • 英文作者:LI Zhen;ZHOU Jia-bin;WANG Xia;ZHAO Ru-song;School of Resources and Environmental Engineering,Wuhan University of Technology;Analysis and Test Center,Shandong Academy of Sciences,QILU University of Technology;
  • 关键词:沸石咪唑酯骨架材料-8 ; 多溴联苯醚 ; 固相微萃取(SPME) ; 气相色谱-串联质谱(GC-MS/MS)
  • 英文关键词:zeolite imidazolate framework-8;;polybrominated biphenyl ethers(PBDEs);;solid phase microextraction(SPME);;gas chromatography-tandem mass spectrometry(GC-MS/MS)
  • 中文刊名:TEST
  • 英文刊名:Journal of Instrumental Analysis
  • 机构:武汉理工大学资源与环境工程学院;齐鲁工业大学(山东省科学院分析测试中心);
  • 出版日期:2018-08-19 21:29
  • 出版单位:分析测试学报
  • 年:2018
  • 期:v.37
  • 基金:国家自然科学基金(21477068);; 山东省重点研发项目(2015GSF117011);; 山东省自然科学基金(ZR2015YL003,ZR2016YL003)
  • 语种:中文;
  • 页:TEST201808001
  • 页数:8
  • CN:08
  • ISSN:44-1318/TH
  • 分类号:13-20
摘要
将沸石咪唑酯骨架材料(ZIF-8)制成固相微萃取涂层,结合气相色谱-三重四极杆串联质谱联用仪(GC-MS/MS),建立了一种快速灵敏分析环境水样中6种痕量多溴联苯醚的方法。采用单因素优化实验得到的最优条件为:不添加Na Cl,萃取温度为50℃,萃取时间为50 min,p H值为7.0,解吸时间和解吸温度分别为5 min和280℃。在最优条件下,该方法测定水样中多溴联苯醚的线性范围为1~1 000 ng/L,检出限为0.08~2.29 ng/L,定量下限为0.23~7.32 ng/L。日内和日间相对标准偏差分别为4.3%~6.5%和6.9%~9.3%。将该方法应用于4种实际环境水样(自来水、泉水、池塘水和垃圾填埋场废水)中多溴联苯醚的检测,回收率为81.6%~109%。
        A rapid and sensitive method was developed for the analysis of 6 polybrominated biphenyl ethers( PBDEs) at trace levels in environmental water samples by gas chromatography-tandem mass spectrometry( GC-MS/MS) with a synthesized zeolite imidazolate framework-8( ZIF-8) as solid phase microextraction coating.The experimental conditions were optimized with single factor tests,and the optimal conditions were as follows:extraction time:50 min,extraction temperature:50 ℃,p H value:7.0,desorption temperature:280 ℃,desorption time:5 min,and without salt addition.Under the optimized conditions,the calibration curves for 6 PBDEs were linear in the range of1-1 000 ng/L with limits of detection and limits of quantitation of 0.08-2.29 ng/L and 0.23-7.32 ng/L,respectively.The intra-day and inter-day RSDs were in the range of 4.3%-6.5% and6.9%-9.3%,respectively.This method was successfully applied in the analysis of PBDEs in 4 environmental water samples( tap water,spring water,pond water and landfill waste water) with recoveries of 81.6%-109%.
引文
[1]Zhou J B,She X K,Xing H Z,Zhao R S.J.Sep.Sci.,2016,39(10):1955-1962.
    [2]Santos M S,Alves A,Madeira L M.Water Res.,2016,88:39-59.
    [3]Shang X H,Dong G X,Zhang H X,Zhang L,Yu X W,Li J G,Wang X Y,Yue B,Zhao Y F,Wu Y N.Food Control,2016,67:240-246.
    [4]Sun J D,Pan L L,Zhan Y,Lu H N,Tasang D C,Liu W X,Wang X L,Li X D,Zhu L Z.Sci.Total Environ.,2016,544:670-676.
    [5]Fontana A R,Silva M F,Mart2Nez L D,Wuilloud R G,Altamirano J C.J.Chromatogr.A,2009,1216(20):4339-4346.
    [6]PietrońW J,Mańagocki P.Talanta,2017,167:411-427.
    [7]Li J X,Sun M Y,Hu X Y,Wu X Q,Chang Q Y,Fan C L.J.Instrum.Anal.(李建勋,孙梦园,胡雪艳,吴兴强,常巧英,范春林.分析测试学报),2017,36(11):1339-1345.
    [8]He J,Li T,Dong M Y,Dong N.J.Instrum.Anal.(何静,李涛,董美玉,董南.分析测试学报),2017,36(10):1185-1190.
    [9]Zhao R S,Wang X,Yan J P,Wang X D.J.Sep.Sci.,2009,32(4):630-636.
    [10]Jiang X Y,Zhang H,Chen X Q.Microchem.Acta,2011,175:341-346.
    [11]Li Q L,Wang X,Liu Y L,Chen X F,Wang M L,Zhao R S.J.Chromatogr.A,2014,1374:58-65.
    [12]Gong S X,Wang X,Chen Y,Cheng C G,Wang M L,Zhao R S.J.Chromatogr.A,2015,1401:17-23.
    [13]Shi Q,Chen Z,Song Z,Li J,Dong J.Angew.Chem.Int.Ed.,2011,123(3):698-701.
    [14]Phan A,Doonan C J,Uriberomo F J,Knobler C B,O'Keeffe M,Yaghi O M.Acc.Chem.Res.,2010,43(1):58-67.
    [15]Seoane B,Zamaro J M,Tellez C,Coronas J.Cryst Eng Comm.,2012,4(9):3103-3107.
    [16]Ge D,Lee H K.J.Chromatogr.A,2011,1218(47):8490-8495.
    [17]Huang J,Ou C,Lv F,Cao Y,Tang H,Zhou Y,Gan N.Talanta,2017,65:326-331.
    [18]Lan H,R9nkk9 T,Parshintsev J,Hartonen K,Ning G,Sakeye M,Sarfraz J,Riekkola M L.J.Chromatogr.A,2016,1486:76-85.
    [19]Zhang J,Zhang W,Bao T,Chen Z.J.Chromatogr.A,2015,1388:9-16.
    [20]Park K S,Ni Z,C^otéA P,Choi J Y,Huang R,Uribe Romo F J,Chae H K,O'Keeffe M,Yaghi M.Proc.Natl.Acad.Sci.USA,2006,103(27):10186-10191.
    [21]Schejn A,Balan L,Falk V,Aranda L,Medjahdi G,Schneider R.Cryst Eng Comm.,2014,16(21):4493-4500.
    [22]Hu Y,Kazemian H,Rohani S,Huang Y,Song Y.Chem.Commun.,2011,47(47):12694-12696.
    [23]Ouyang G,Vuckovic D,Pawliszyn J.Chem.Rev.,2011,111(4):2784-2814.
    [24]Yu H,Zhao Y F,Yang L X,Chen X F.Anal.Methods,2017,48:6808-6813.
    [25]Zhang H,Lee H K.J.Chromatogr.A,2011,1218(28):4509-4516.
    [26]Naing N N,Li S F,Lee H K.J.Chromatogr.A,2016,1458:25-34.
    [27]Wang J X,Jiang D Q,Gu Z Y,Yan X P.J.Chromatogr.A,2006,1137(1):8-14.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700