摘要
不同于城市住房,农村住房主要由农民自建完成,受建筑技术、条件、施工工艺等限制,农村自建房建筑质量参差不齐,构造措施不到位等,导致存在地震安全隐患。本文通过对郯庐断裂带安徽段农村自建房的房屋结构及分布、地基基础、建筑构造措施及构件强度等抽样进行检测调查,总结分析区域内农村自建房的地震安全性能,为防震减灾提供参考。
Rural buildings,different from urban ones,are mainly self-built.Due to building technology,condition and construction technology,the quality of rural self-built buildings are uneven with improper construction measures,which lead to potential seismic safety hazard.The paper first makes a sample survey of rural self-built buildings in Anhui part of the Tan-Lu Fault Zone on the building structure and distribution,foundation,construction measures and component strength.The paper then summarizes and analyzes the seismic safety performance of rural self-built buildings in the area in order to provide the reference for mitigating earthquake disasters.
引文
[1]颜琼,李建耀.当前我国农村自建房过度化的实证研究——以江西省为例[J].科技创新与应用,2015(4):14-16.
[2]周安.基于抽样调查的安徽农村民居震害预测与减灾对策[J].地震学报,2009,31(1):100-107.
[3]中华人民共和国建设部.GB/T 50344-2004建筑结构检测技术标准[S].北京:中华人民共和国建设部,国家质量监督检验检疫总局,联合发布,2004-09-02.
[4]袁景衡.农村自建房建设形态的转变分析——以陕南汉中、安康、商洛三地为例[J].西安建筑科技大学学报(社会科学版),2015,34(4):14-18.
[5]陕西省建筑科学研究院.JGJ/T 23-2011回弹法检测混凝土抗压强度技术规程[S].北京:中国建筑工业出版社,2011.
[6]苏小妹,苏小娟.安徽省农村民居地震安全问题调查研究[J].灾害学,2008,23(3):140-144.
[7]方小亮,厉宝根.农村自建房施工安全隐患的成因与解决途径[J].中国建设信息,2009(6):32-33.
[8]蒋敏,程桦.郯庐断裂带安徽区段农居地震安全性能调查[J].建筑结构,2015,45(8):35-39.
[9]朱伯肃.关于农村自建房现状及房屋安全的思考[J].福建建材,2016(7):38-39.
[10]江浩.川东丘陵地区农村自建房现状调查研究[J].边疆经济与文化,2014(1):14-16.
(1)小于1级的为超微震;1-3级为微震,人们一般不易觉察;3-4.5级为有感地震,人们能够感觉到,但一般不会造成破坏;4.5-6级为中强震,可造成破坏,但破坏轻重与震源深度、震中距等有关;6-7级为强震;7-8级为大地震;8级以及8级以上为巨大地震。
(2)建筑构件抗压强度平均值及标准差应按下式计算:■■式中:mfccu:构件测区强度换算值的平均值; n:被抽检构件的测区之和;fccu·i:测区强度换算值;sfccu:构件强度换算值的标准差。