摘要
依据国家标准GB 5009.266—2016《食品安全国家标准食品中甲醇的测定》中气相色谱法测定食品中甲醇含量的测定原理,检测食用酒精中甲醇的含量,用建立数学模型的方法对结果的不确定度进行评估和计算。对标准溶液的配制、测量重复性、仪器稳定性各分量不确定度进行分析,得到了各分量不确定度和合成不确定度,最终得出更加客观的结果。
According to the principles in national standard GB 5009.266-2016, we measured the methanol content in edible alcohol and further established mathematical models to assess and calculate the uncertainties in the determination process. Besides, the uncertainties in standard solution preparation, repeated measurement and instrument stability were analyzed to obtain the uncertainties of each component and the synthetic uncertainties. As a result, reliable and accurate measurement results could be achieved.
引文
[1]全国法制计量管理计量技术委员会.测量不确定度评定与表示:JJF 1059.1—2012[S].北京:中国标准出版社,2013.
[2]国家卫生和计划生育委员会.食品安全国家标准食品中甲醇的测定:GB 5009.266—2016[S].北京:中国标准出版社,2017.
[3]曹小彦,张燕,黄雄伟,等.气相色谱法测定葡萄酒中甲醇含量不确定度评定[J].食品与机械,2013,29(6):76-78.
[4]黄丽金,童优芸,袁勇军.气相色谱法测定白酒中甲醇含量测量结果不确定度的评定[J].安徽农业科学,2013,41(13):5952-5953.
[5]常春艳.白酒中甲醇对人体的危害[J].中国商检,1998(5):37.