多次激发扩散磁共振成像中运动伪影及偏共振伪影的联合矫正
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Joint Correction for Motion Artifacts and Off-resonance Artifacts in Multi-shot Diffusion Magnetic Resonance Imaging
  • 作者:吴文川 ; 方晟 ; 郭华
  • 英文作者:WU Wenchuan;FANG Sheng;GUO Hua;Center for Biomedical Imaging Research,Department of Biomedical Engineering,School of Medicine,Tsinghua University;Institute of Nuclear and New Energy Technology,Tsinghua University;
  • 关键词:扩散磁共振成像 ; 变密度螺旋线序列 ; 运动伪影矫正 ; 去模糊
  • 英文关键词:diffusion magnetic resonance imaging;;variable density spiral;;motion artifact correction;;deblurring
  • 中文刊名:SWGC
  • 英文刊名:Journal of Biomedical Engineering
  • 机构:清华大学生物医学工程系生物医学影像研究中心;清华大学核能与新能源技术研究院;
  • 出版日期:2014-06-25
  • 出版单位:生物医学工程学杂志
  • 年:2014
  • 期:v.31
  • 基金:国家自然科学基金资助项目(61271132,81101030)
  • 语种:中文;
  • 页:SWGC201403036
  • 页数:6
  • CN:03
  • ISSN:51-1258/R
  • 分类号:185-189+198
摘要
针对多次激发扩散磁共振成像中的运动伪影和偏共振伪影,本文提出了一种联合矫正方法,可以同时去除两种伪影,而且不需要额外采集运动导航数据和主磁场不均度图。该方法使用多次激发变密度螺旋线序列采集数据,通过自动偏共振矫正算法去除模糊,运动引入的相位误差在去除模糊的过程中采用直接法或迭代法矫正。在体磁共振成像实验表明,所提出的联合矫正方法可有效去除运动伪影和偏共振效应引起的图像模糊,获得结构清晰的成像结果,且不会增加扫描时间。
        Aiming at motion artifacts and off-resonance artifacts in multi-shot diffusion magnetic resonance imaging(MRI),we proposed a joint correction method in this paper to correct the two kinds of artifacts simultaneously without additional acquisition of navigation data and field map.We utilized the proposed method using multi-shot variable density spiral sequence to acquire MRI data and used auto-focusing technique for image deblurring.We also used direct method or iterative method to correct motion induced phase errors in the process of deblurring.In vivo MRI experiments demonstrated that the proposed method could effectively suppress motion artifacts and off-resonance artifacts and achieve images with fine structures.In addition,the scan time was not increased in applying the proposed method.
引文
[1]LE BIHAN D,BRETON E,LALLEMAND D,et al.MR imaging of intravoxel incoherent motions:application to diffusion and perfusion in neurologic disorders[J].Radiology,1986,161(2):401-407.
    [2]MILLER K L,PAULY J M.Nonlinear phase correction for navigated diffusion imaging[J].Magn Reson Med,2003,50(2):343-353.
    [3]PIPE J G,FARTHING V G,FORBES K P.Multishot diffusion-weighted FSE using PROPELLER MRI[J].Magn Reson Med,2002,47(1):42-52.
    [4]LIU C L,BAMMER R,KIM D H,et al.Self-navigated interleaved spiral(SNAILS):application to high-resolution diffusion tensor imaging[J].Magn Reson Med,2004,52(6):1388-1396.
    [5]LLINGSON B M,SULAIMAN O,KURPAD S N.Highresolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated,interleaved,variable-density spiral acquisition(SNAILS-DTI)[J].Magn Reson Imaging,2010,28(9):1353-1360.
    [6]KARAMPINOS D C,VAN A T,OLIVERO W C,et al.High-resolution diffusion tensor imaging of the human pons with a reduced field-of-view,multishot,variable-density,spiral acquisition at 3T[J].Magn Reson Med,2009,62(4):1007-1016.
    [7]SHENBERG I,MACOVSKI A.Inhomogeneity and multiple dimension considerations in magnetic resonance imaging with time-varying gradients[J].IEEE Trans Med Imaging,1985,4(3):165-174.
    [8]NOLL D C,MEYER C H,PAULY J M,et al.A homogeneity correction method for magnetic resonance imaging with time-varying gradients[J].IEEE Trans Med Imaging,1991,10(4):629-637.
    [9]KADAH Y M,HU X.Simulated phase evolution rewinding(SPHERE):a technique for reducing B0inhomogeneity effects in MR images[J].Magn Reson Med,1997,38(4):615-627.
    [10]MAN L C,PAULY J M,MACOVSKI A.Improved automatic off-resonance correction without a field map in spiral imaging[J].Magn Reson Med,1997,37(6):906-913.
    [11]NOLL D C,PAULY J M,MEYER C H,et al.Deblurring for non-2D Fourier transform magnetic resonance imaging[J]. Magn Reson Med,1992,25(2):319-333.
    [12]KIM D H,ADALSTEINSSON E,SPIELMAN D M.Simple analytic variable density spiral design[J].Magn Reson Med,2003,50(1):214-219.
    [13]LIU C L,MOSELEY M E,BAMMER R.Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling[J].Magn Reson Med,2005,54(6):1412-1422.
    [14]TRUONG T K,GUIDON A.High-resolution multishot spiral diffusion tensor imaging with inherent correction of motion-induced phase errors[J].Magn Reson Med,2014,71(2):790-796.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700