摘要
目的:分析妇幼保健院用电情况,为医院制定节能降耗措施提供依据。方法:针对用能人数以及天气情况两方面,利用Origin8.0数据处理软件分析医院的用电数据,以医院能耗大的设备为研究对象,从时间差异化管理和使用无功功率补偿设备等角度,提出节能措施。结果:随着用能人数、30℃以上与0℃以下天气的增加,用电量明显呈现增长的趋势。结论:节能措施不仅能够为医院节省用电成本,而且能够为国家的能源降耗提供借鉴。
Objective:To provide a basis for the hospital to make corresponding measures for energy-saving and consumption reduction by studying the electricity consumption of the MCH hospital in recent years. Methods:Firstly,it takes the energy-intensive equipment in the MCH hospital as the research object according to the electricity data of hospital by Origin 8.0, and makes a detailed analysis on the number of people who use energy and the weather conditions. Secondly, the effective energy-saving measures are proposed from various angles, including time differential management and the use of reactive power compensation equipment. Results:The results show that with the increase of the number of people using energy,the weather above 30 degrees and below 0 degrees,the electricity consumption obviously takes on a growth trend. Conclusion:Energy-saving measures can not only save electricity costs for hospitals, but also provide a significant reference for national energy reduction.
引文
[1]潘常青.我院后勤能源管理实践与评价[J].中华医院管理杂志,2014,30(1):64-66.
[2]窦逸峰,杨洪海,朱学锦,等.上海大型医院能耗评估及节能分析[J].节能技术,2015,33(4):362-365.
[3]冒晓飚,石高寒,黄安山,等.医院用电现状及节电措施探讨[J].能源与节能,2017,22(2):82-83.
[4]任占飞,王媛媛.浅析工厂供配电系统无功补偿的益处[J].科技创新与应用,2014,26(2):27-28.
[5]李洪琳,张欣,王世鑫,等.综合医院节电评价指标体系构建研究[J].中华医院管理杂志,2017,33(7):537-539.