以深圳某超高层建筑为例,在分析其结构特点的基础上,基于抗震设计方法,设定抗震性能目标为C级,并对其进行整体结构弹性计算、弹性时程分析、抗震性能验算以及罕遇地震作用下的动力弹塑性分析,根据计算结果,采取相应措施确保结构安全可靠,可为类似工程设计提供参考。
This paper takes a super high-rise building in Shenzhen as an example. Based on the analysis of its structural characteristics and the seismic resistance design method, the seismic performance target is set to C grade.The overall structural elastic calculation, elastic time history analysis, seismic resistance verification of the super high-rise building are carried out. At the same time, dynamic elastic-plastic analysis under rare earthquakes is performed, according to the calculation results, corresponding measures are taken to ensure the structure safety and reliable.
引文
[1] GB 50009-2012建筑结构荷载规范[S].北京:中国建筑工业出版社, 2012.
[2] GB 50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社, 2010.
[3]住建部超限高层建筑工程抗震设防专项审查技术要点[R], 2015.
[4] GB JGJ3-2010高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社, 2010.
[5]邹扬帆,陈宁旭.广州某小区高层住宅超限结构抗震设计[J].广州建筑, 2005(4):17-21.
[6]何智威,唐嘉敏.万博购物中心超高层结构设计及抗震性能分析[J].广州建筑, 2018(4):6-10.
[7]林瑶明,林凡,方小丹,韦宏.广州某国际金融中心超限高层结构设计[J].建筑结构, 2012, 42(7):17-21.
[8]丁洁民,吴宏磊,赵昕.我国高度250m以上超高层建筑结构现状与分析进展[J].建筑结构学报, 2014,35(3):1-7.
[9]罗永峰,王磊,李海峰,陈文辉.罕遇地震下上海中心超高层的性能化抗震设计[J].同济大学学报(自然科学版), 2011, 39(4):467-473.
[10]谢俊,蒋涤非,陈定球.深圳大厦超限高层结构抗震设计[J].广东土木与建筑, 2017, 47(9):175-180.