掺钢渣钢屑复合砂浆电磁屏蔽性能研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Research on electrom agnetic shielding effectiveness of composite mortar with steel slag and steel crape
  • 作者:赵若红 ; 区浩文 ; 傅继阳 ; 庄志勇
  • 英文作者:ZHAO Ruohong;OU Haowen;FU Jiyang;ZHUANG Zhiyong;Research Center for Structural Safety and Health Monitoring of Guangdong Education Department,Guangzhou Municipal Key Laboratory for Structural Safety and Health Monitoring,Engineering Technology Research and Development Center for Structural Wind Resistance and Health Monitoring in Guangdong Province,Guangzhou University;
  • 关键词:复合砂浆 ; 钢渣 ; 钢屑 ; 电阻率 ; 电磁屏蔽
  • 英文关键词:composite mortar;;steel slag;;steel scrap;;electrical resistivity;;electromagnetic shielding
  • 中文刊名:HLTF
  • 英文刊名:Concrete
  • 机构:广州大学 广东高校结构安全与健康监测工程技术研究中心,广州市结构安全与健康监测重点实验室,广东省工程结构抗风与健康监测工程技术研究开发中心;
  • 出版日期:2015-03-27
  • 出版单位:混凝土
  • 年:2015
  • 期:No.305
  • 基金:国家自然科学基金青年基金项目(51308138);; 教育部高等学校博士点学科专项基金项目(20124410120004);; 广东省自然科学基金面上项目(S2012010009831);; 广州市科技计划项目(2014J4100141)
  • 语种:中文;
  • 页:HLTF201503038
  • 页数:4
  • CN:03
  • ISSN:21-1259/TU
  • 分类号:126-129
摘要
选取钢渣和钢屑两种工业废弃物,混合掺入砂浆中制备得到环保低成本的电磁屏蔽复合砂浆,在测定其电阻率的基础上测量其在300 MHz~3 GHz频率范围内的电磁屏蔽效能。试验结果表明:钢渣钢屑复合砂浆的电磁屏蔽效能随着导电材料掺量的增加而增大,1 cm厚度试件屏蔽效能峰值达到16.63 d B;复合砂浆屏蔽效能随厚度增加显著增大,3 cm试件屏蔽效能峰值达36.31 d B,比同配合比1 cm试件增大了118%;屏蔽效能峰值所对应的频率也随导电物掺量与试件厚度的改变而变化。
        Steel slag and steel crape,two industrial waste materials,were chosen to mix to add into cement system to produce electromagnetic shielding composite mortar that was low cost and environmental protection. Its electromagnetic shielding effectiveness from 300 MHz to 3 GHz was studied by flange coaxial method on the basis of testing its electrical conductivity. The test results show that when the conductive material increase,the shielding effectiveness of composite was improved and the maximum value reached 16.63 d B; With the increase of thickness,shielding effectiveness is more obvious; The frequency of the shielding effectiveness of extremum corresponding also changes with the increase of thickness.
引文
[1]曾祥云,李家俊,师春生.碳纤维在电磁功能复合材料中的应用[J].材料导报,1998,12(1):64-67.
    [2]姜勇,王刚.电磁屏蔽玻璃在电磁屏蔽方舱上的应用[J].安全与电磁兼容,2005(1):37-39.
    [3]杨华明,胡岳华,张慧慧.重晶石基锑掺杂Sn O2导电粉末用于导电涂料及其屏蔽特性[J].功能材料,2006,32(9):1433-1435.
    [4]CAO Jingyao,CHUNG D D L.Coke powder as an admixture in cement for electromagnetic shielding[J].Carbon,2003,(41):2434-2435.
    [5]RAY M,GEORGE J J.An investigation of the electromagnetic shielding effectiveness of ethylene vinyl acetate elastomer reinforced with carbon nanpfillers[J].Polymers and Polymer Composites,2010,18(2):59-65.
    [6]KIMA S W,YOONB Y W,LEEA S J,et al.Electromagnetic shielding properties of soft magnetic powder/polymer composite films for the application to suppress noise in the radio frequence range[J].Journal of Magnetism and Materials,2007,316:473-474.
    [7]杨玉山,董发勤,邓强.掺石墨/碳纤维电磁屏蔽砂浆的研究[J].功能材料,2011,10(42):1844-1846.
    [8]GB/T 17671—1999,水泥胶砂强度检验方法(ISO)[S].
    [9]GJ/B 6190—2008,电磁屏蔽材料屏蔽效能测量方法[S].

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700