摘要
本文中作者基于加速热老化评估的基本原理,结合标准讨论了干式变压器热老化评估实施的逻辑,提出了具操作性的方法。
Based on the principle of accelerated thermal aging evaluation and standards,the logic of thermal aging evaluation of dry-type transformer is discussed by the author in this paper. The operatable methods are presented.