摘要
从降低能耗角度出发,分析了地铁车站通风空调系统的构造及能耗水平,重点探讨了其节能运行的几个要点,从活塞风利用、节能运行管理、建立蓄冷(热)空调系统、管路优化设计、余热回收利用等方面,介绍了地铁车站空调系统的优化方案,旨在降低通风空调系统的能耗,推动地铁的良好发展。
From the perspective of energy saving and consumption reduction,this paper analyzes structure and energy consumption level of the ventilation and air conditioning system of subway stations,focuses on several key points of its energy saving operation. This paper introduces the optimization scheme of the air conditioning system of subway station from the aspects of piston wind utilization,energy saving operation management,establishment of cold storage(thermal) air conditioning system,pipeline optimization design,and waste heat recovery and utilization.The aim is to reduce the energy consumption of the ventilation and air conditioning system and promote the good development of the subway.
引文
[1]刘冲.浅谈某地铁站通风空调系统运行模式及控制系统[J].建筑工程技术与设计,2014(1):236-237.
[2]王慧.地铁列车活塞风的数值计算与通风节能探讨[D].南京:南京理工大学,2012.
[3]朱永赤,郑晋丽,居炜.地铁空调通风系统能耗解析[J].地下工程与隧道,2007(4):30-33.
[4]王前进,翟晓强,王晓保,等.国内地铁车站空调系统研究进展[J].建筑科学,2012,28(8):97-103.
[5]罗佳.地铁通风空调系统节能运行策略研究[D].广州:广州大学,2015.
[6]杨昭,余龙清,马锋,等.地铁通风空调系统的逐时优化节能控制策略[J].天津大学学报(自然科学与工程技术版),2012,45(7):599-603.