摘要
目的改进茴拉西坦的有关物质测定方法。方法采用高效液相色谱法,以C18为色谱柱,流动相为乙腈-水(35∶65),检测波长为254nm。结果茴拉西坦与其降解产物在该色谱条件下能够有效分离。结论该方法准确可靠,可用于测定茴拉西坦的有关物质测定。
OBJECTIVE To improve an HPLC method for determination of the related substances in aniracetam.METHODS The column was C18 colum.Mobile phase was acetonitrile-water(35∶65).The detection wavelength was 254 nm.RESULTS Aniracetam and its related substances can be separated effectively by this method.CONCLUSION The method is accurate and reliable.It can be used for the related substances determination in aniracetam.
引文
[1]WS1-(X-027)-2001Z(国家药品监督管理局国家药品标准)[S].2001:965-966.
[2]YBH01292006(国家食品药品监督管理局标准)[S].2006.
[3]XU J X.Determination of related substances in aniracetamdispersible tablets by HPLC[J].Acad J Guangdong CollPharm(广东药学院学报),2009,25(4):373-375.
[4]LI F L,CAO X Q,LI D J,et al.Determination of aniracetamgranules and its related substances by HPLC[J].ShangdongPharm Ind(山东医药工业),2002,21(5):9.