摘要
利用拉格朗日方程建立了核筒悬挂建筑结构体系运动方程,采用Longe-Kuta方法求解体系地震动力响应时程。实例计算结果表明,阻尼器系数对悬挂结构的减震效果具有明显影响,楼层位移沿结构高度的分布趋于均匀,且相对于普通无悬挂结构其层间位移、层位移、层速度以及层加速度大幅度减小,而且存在一个优化的阻尼器系数使得结构层间位移有最小值。
The motion equation for the core tube suspension building structure is established though Lagrange equation,and the response interval of seismic force of the system obtained with Longe Kuta method.The calculation results show that the damping coefficient of the damper has an obvious influence on the damping effect of the suspension structure,that the floor displacement tends to be uniform along the height of the structure,and the inter-story displacement,floor displacement,displacement velocity and acceleration are greatly reduced compared with the ordinary none-suspension structure,and that there exists an optimal damper coefficient which minimizes structure displacement.
引文
[1]刘晶波,杜修力.结构动力学[M].北京:机械工业出版社,2006:152-178.
[2]葛楠,苏幼坡,王兴国,等.竖向刚度对FPS滑移摩擦摆系统隔震性能影响研究[J].工程抗震与加固改造,2010,32(4):20-25.
[3]周锡元,阎维明,杨润林.建筑结构的震动、减振和振动控制[J].建筑结构学报,2002,23(2):2-11.