  • 作者:陈洪砚 ; 陈翰 ; 刘婷玉 ; 王侨
  • 英文作者:CHEN Hongyan;CHEN Han;LIU Tingyu;WANG Qiao;Tieling Municipal Research Institute of Environmental Protection;State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology;Tieling Lvzhou Environment Protection Engineering Co., Ltd.;
  • 关键词:肉禽屠宰加工废水 ; 沉砂隔油 ; 厌氧折流板反应器 ; 序批式活性污泥反应器
  • 英文关键词:poultry slaughtering and processing wastewater;;grit and oil separator;;anaerobic baffled reactor;;sequencing batch reactor
  • 中文刊名:SCLJ
  • 英文刊名:Technology of Water Treatment
  • 机构:铁岭市环境保护科学研究院;哈尔滨工业大学城市水资源与水环境国家重点实验室;铁岭市绿洲环保工程有限公司;
  • 出版日期:2017-06-14 11:25
  • 出版单位:水处理技术
  • 年:2017
  • 期:v.43;No.305
  • 语种:中文;
  • 页:SCLJ201706029
  • 页数:4
  • CN:06
  • ISSN:33-1127/P
  • 分类号:129-131+134
摘要
针对肉禽屠宰加工废水中悬浮杂质多、有机物浓度高等特点,以辽宁省铁岭市某肉禽加工厂废水处理工程为实例,采用沉砂隔油-ABR/O-SBR组合工艺对肉禽屠宰加工废水进行处理。工程结果表明,本组合工艺在进水COD为1 330 mg/L,BOD_5为813 mg/L,SS质量浓度为1 443 mg/L,氨氮质量浓度为116.6 mg/L的情况下,处理后最终出水COD为31.9 mg/L,BOD_5为8.6 mg/L,SS质量浓度为7.2 mg/L,氨氮质量浓度为2.88 mg/L,去除率分别高达97.60%、98.94%、99.50%和97.53%。该组合工艺出水水质可稳定满足DB 21/1627-2008,同时其运行费用仅为0.708元/m3。
        A combined process of grit and oil separator-ABR/O-SBR was employed in the practical engineering project of poultry slaughtering and processing wastewater treatment in some poultry processing plant in Tieling. The poultry slaughtering and processing wastewater has high concentrations of suspended impurities and organic matters. The result showed that when the original concentrations of COD, BOD_5, suspended solids and ammonia nitrogen was 1 330 mg/L, 813 mg/L, 1 443 mg/L and 116.6 mg/Lrespectively, the effluent concentrations of COD, BOD_5, suspended solids and ammonia nitrogen was 31.9 mg/L, 8.6 mg/L, 7.2 mg/L and 2.88 mg/L, respectively, which indicated that the final removal rates could respectively reach 97.60%,98.94%, 99.50% and 97.53%. The effluent quality after this combined process treatment could meet the demand of Integrated Wastewater Discharge Standard of Liaoning Province(DB 21/1627-2008). And the operating cost was only 0.708 Yuan/m~3.
引文
[1]唐玲,孙晓峰,宋云.中国屠宰行业的总氮减排趋势分析[J].环境污染与防治,2015,37(3):90-93.
    [2]刘威,陈明辉,尚金城.改进型水解-接触氧化工艺在小型屠宰企业废水处理中的应用研究[J].工业水处理,2011,31(1):76-79.
    [3]李慧,李涛,王文,等.屠宰废水处理工程的设计及运行[J].中国给水排水,2012,28(24):64-66,70.
    [4]张显龙,胡娜.屠宰废水处理工艺设计与运行研究[J].工业水处理,2012,32(4):83-84,92.
    [5]贾艳萍,姜修平,姜成,等.屠宰废水处理技术与应用进展[J].水处理技术,2015,41(5):5-10.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700